UIBL-P Dinosaur 12V LONG BOARD W/POST
UIBL-P Dinosaur 12V LONG BOARD W/POST
The UIBL-P Dinosaur Electronics Long Board is a premium 12-volt DC universal ignition control board designed for RV furnaces and mobile heating systems. Featuring a long-board configuration with post-style terminals, the UIBL-P provides a durable and reliable replacement solution for a variety of OEM RV furnace ignition boards. Designed and manufactured by Dinosaur Electronics, this board is known for its robust construction, advanced diagnostics, and dependable performance in demanding RV environments.
The UIBL-P controls critical furnace functions including ignition sequencing, flame sensing, safety lockout protection, and burner operation, helping restore reliable heating performance in travel trailers, fifth wheels, motorhomes, and other RV applications.
Cross-Reference
- UIBL-P
- UIBLP
- Dinosaur UIBL-P
- Dinosaur Electronics UIBL-P
- Universal Ignition Board Long
- 12V RV Furnace Control Board
- Long Board with Posts
Direct Replacement
Universal replacement ignition board for many compatible RV furnace applications.
Always verify terminal style, wiring configuration, and furnace compatibility before installation.
Compatible Brands
Compatible with many RV furnace systems, including select models from:
- Atwood
- Hydro Flame
- Dometic
- Suburban
- Duo-Therm
- Everest Star
- Other compatible 12V RV furnace applications
Verify furnace model compatibility before ordering.
Application
- RV furnaces
- Travel trailer heating systems
- Fifth wheel furnaces
- Motorhome furnaces
- Mobile heating systems
- 12V ignition control applications
Related Components
- Sail Switches
- Flame Sensors
- Igniters
- Limit Switches
- Blower Motors
- Gas Valves
- Thermostats
- Wiring Harnesses
Technician Notes
- Genuine Dinosaur Electronics replacement board.
- 12 VDC operation.
- Long-board design with post terminals.
- Designed specifically for RV furnace applications.
- Controls ignition sequence, flame verification, and safety shutdown functions.
- Known for improved reliability compared to many original equipment boards.
- Verify proper furnace grounding before replacing the control board.
- Inspect sail switch, limit switch, and igniter operation when diagnosing board failures.
Common Symptoms of Failure
- Furnace will not ignite
- No heat operation
- Ignition lockout conditions
- Blower runs without burner ignition
- Intermittent furnace operation
- No response to thermostat demand
- Flame sensing faults
- Burned or damaged control board components
Installation Tips
- Disconnect 12V DC power before servicing.
- Label all wire locations before removing the original board.
- Verify compatibility with the furnace model.
- Transfer wiring to the new board one connection at a time.
- Inspect terminal ends and connectors for corrosion.
- Confirm proper grounding and power supply voltage.
- Restore power and test furnace operation.
- Verify proper ignition, flame sensing, and blower operation.
Recommended Inspection Items
- Sail switch condition
- Igniter operation
- Flame sensor circuit
- Gas valve performance
- Blower motor operation
- Thermostat wiring
- Ground connections
- Furnace heat exchanger
- 12V DC power supply