UIB 24VAC Dinosaur (002) W/FAN CONTROL & PINS

UIB 24VAC Dinosaur (002) W/FAN CONTROL & PINS

  • $ 159.95
    Unit price per 
  • Save $ 27.50
Shipping calculated at checkout.


UIB 24VAC W/FAN CONTROL & PINS 002 Dinosaur 

The UIB 24VAC with Fan Control & Pins by Dinosaur Electronics is a universal replacement ignition control board designed for a wide range of residential gas furnaces operating on 24 VAC control voltage. Engineered as a versatile service replacement, this universal ignition board combines ignition control and fan control functionality into a single module, helping restore reliable furnace operation when OEM control boards fail.

Manufactured in the USA by Dinosaur Electronics, the UIB is designed for dependable performance and includes installation pins and hardware to simplify replacement in compatible furnace applications. Its universal design makes it an excellent service inventory item for HVAC contractors seeking a reliable replacement for numerous discontinued or hard-to-find ignition boards.


Cross-Reference

  • UIB
  • Dinosaur UIB
  • UIB 24VAC
  • Universal Ignition Board
  • Dinosaur Electronics Ignition Board
  • Fan Control Ignition Module
  • PC 659 PARK MODEL USE DPUIBS24VAC

Direct Replacement

Universal replacement ignition control board for many compatible furnace applications.

Always verify wiring configuration, ignition type, and furnace compatibility before installation.


Compatible Brands

May be used in compatible applications from:

  • Coleman
  • York
  • Luxaire
  • Fraser-Johnston
  • Goodman
  • Amana
  • Rheem
  • Ruud
  • Carrier
  • Bryant
  • Payne
  • Trane
  • American Standard
  • Lennox
  • Nordyne
  • Intertherm
  • Miller

And many other gas furnace applications utilizing compatible 24VAC ignition controls.


Application

  • Gas furnaces
  • Residential HVAC systems
  • Ignition control replacement
  • Fan control replacement
  • Furnace repair and service
  • Universal retrofit applications

Related Components

  • Flame Sensors
  • Hot Surface Ignitors
  • Spark Ignitors
  • Pressure Switches
  • Limit Switches
  • Draft Inducer Motors
  • Gas Valves
  • Wiring Harnesses

Technician Notes

  • Universal ignition control board with integrated fan control.
  • Designed for 24 VAC furnace systems.
  • Includes installation pins and mounting hardware.
  • Excellent replacement option for obsolete OEM ignition boards.
  • Verify all thermostat, safety, and ignition wiring prior to installation.
  • Follow Dinosaur Electronics wiring instructions carefully.
  • Inspect all furnace safety controls before condemning the board.

Common Symptoms of Failure

  • No heat operation
  • Furnace will not ignite
  • Blower motor not operating correctly
  • Ignition sequence failures
  • Intermittent furnace operation
  • Control board fault conditions
  • No response to thermostat call
  • Burned or damaged circuit board components

Installation Tips

  1. Disconnect electrical power before servicing.
  2. Photograph and label all wiring connections.
  3. Verify compatibility with the furnace ignition system.
  4. Transfer wiring according to Dinosaur Electronics instructions.
  5. Secure the board using the supplied mounting hardware.
  6. Inspect safety circuits before startup.
  7. Restore power and verify board diagnostics.
  8. Test the furnace through a complete heating cycle.

Recommended Inspection Items

  • Flame sensor condition
  • Ignitor operation
  • Gas valve performance
  • Pressure switch operation
  • High-limit switches
  • Draft inducer motor
  • Thermostat wiring
  • Transformer voltage
  • Blower motor operation

We Also Recommend