3F01-110 Copeland Comfort Control (White Rodgers) Fan Switch F110-20F
3F01-110 Copeland Comfort Control (White Rodgers) Fan Switch F110-20F
The 3F01-110 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 110°F fixed cut-in temperature and a 20°F differential, this close-on-rise temperature switch automatically energizes the blower when operating temperatures are reached and turns the fan off as the system cools.
Cross-Reference
- 3F01-110
- 3F01110
- F110-20F
- White-Rodgers 3F01-110
- Copeland Comfort Control 3F01-110
- 60T12 Series Fan Switch
Direct OEM
White-Rodgers 3F01-110
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- Nordyne
- Intertherm
- Miller
- Coleman
- York
- Universal HVAC Applications
Application
Used in HVAC and heating equipment to:
- Control blower fan operation
- Close contacts at 110°F on temperature rise
- Open contacts after cooling by approximately 20°F
- Prevent circulation of cold air during furnace startup
- Improve heating efficiency and comfort
- Automate blower fan cycling
Related Components
- Fan Switch
- Fan & Limit Control
- High Limit Switch
- Blower Relay
- Furnace Control Board
- Blower Motor
- Transformer
- Thermostat
- Temperature Safety Controls
Technician Notes
The 3F01-110 is an automatic reset, close-on-rise snap disc fan switch. The contacts remain open during lower temperatures and close when the sensing surface reaches 110°F, energizing the blower circuit. As temperature drops approximately 20°F, the contacts reopen, shutting off the blower.
Always verify temperature ratings, switch action, terminal configuration, and mounting style before replacement. A failed fan switch can cause delayed blower operation, continuous blower operation, or overheating conditions.
Common Symptoms of Failure
- Blower motor will not start
- Blower runs continuously
- Delayed blower operation
- Reduced heating efficiency
- Furnace overheating
- Short cycling blower motor
- No continuity through switch contacts
- Uneven comfort levels
Installation Tips
- Disconnect power before servicing.
- Verify the replacement matches the original temperature rating.
- Confirm switch action is "Close on Rise."
- Mount securely on the original sensing surface.
- Inspect wiring terminals for corrosion or heat damage.
- Check blower motor operation before replacement.
- Verify fan-on and fan-off temperatures after installation.
- Test a complete heating cycle before returning equipment to service.
Recommended Inspection Items
- Blower motor amperage
- Air filter condition
- Heat exchanger temperature
- Wiring terminals
- Blower relay operation
- Furnace control board
- Temperature rise across furnace
- Supply and return airflow
- Blower wheel cleanliness
Controls, Temperature, 110 degrees F Fixed Cut-in Temperature, 90 degrees F Fixed Cut-out Temperature, Close on Rise Switch Action, Snap Disc Auto Reset Fan Switch (60T12-610044)