3F01-110 Copeland Comfort Control (White Rodgers) Fan Switch F110-20F

  • $ 14.95
    Unit price per 
  • Save $ 10.04
Shipping calculated at checkout.


3F01-110 Copeland Comfort Control (White Rodgers) Fan Switch F110-20F

The 3F01-110 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 110°F fixed cut-in temperature and a 20°F differential, this close-on-rise temperature switch automatically energizes the blower when operating temperatures are reached and turns the fan off as the system cools.


Cross-Reference

  • 3F01-110
  • 3F01110
  • F110-20F
  • White-Rodgers 3F01-110
  • Copeland Comfort Control 3F01-110
  • 60T12 Series Fan Switch

Direct OEM

White-Rodgers 3F01-110


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • Nordyne
  • Intertherm
  • Miller
  • Coleman
  • York
  • Universal HVAC Applications

Application

Used in HVAC and heating equipment to:

  • Control blower fan operation
  • Close contacts at 110°F on temperature rise
  • Open contacts after cooling by approximately 20°F
  • Prevent circulation of cold air during furnace startup
  • Improve heating efficiency and comfort
  • Automate blower fan cycling

Related Components

  • Fan Switch
  • Fan & Limit Control
  • High Limit Switch
  • Blower Relay
  • Furnace Control Board
  • Blower Motor
  • Transformer
  • Thermostat
  • Temperature Safety Controls

Technician Notes

The 3F01-110 is an automatic reset, close-on-rise snap disc fan switch. The contacts remain open during lower temperatures and close when the sensing surface reaches 110°F, energizing the blower circuit. As temperature drops approximately 20°F, the contacts reopen, shutting off the blower.

Always verify temperature ratings, switch action, terminal configuration, and mounting style before replacement. A failed fan switch can cause delayed blower operation, continuous blower operation, or overheating conditions.


Common Symptoms of Failure

  • Blower motor will not start
  • Blower runs continuously
  • Delayed blower operation
  • Reduced heating efficiency
  • Furnace overheating
  • Short cycling blower motor
  • No continuity through switch contacts
  • Uneven comfort levels

Installation Tips

  1. Disconnect power before servicing.
  2. Verify the replacement matches the original temperature rating.
  3. Confirm switch action is "Close on Rise."
  4. Mount securely on the original sensing surface.
  5. Inspect wiring terminals for corrosion or heat damage.
  6. Check blower motor operation before replacement.
  7. Verify fan-on and fan-off temperatures after installation.
  8. Test a complete heating cycle before returning equipment to service.

Recommended Inspection Items

  • Blower motor amperage
  • Air filter condition
  • Heat exchanger temperature
  • Wiring terminals
  • Blower relay operation
  • Furnace control board
  • Temperature rise across furnace
  • Supply and return airflow
  • Blower wheel cleanliness

 

Controls, Temperature, 110 degrees F Fixed Cut-in Temperature, 90 degrees F Fixed Cut-out Temperature, Close on Rise Switch Action, Snap Disc Auto Reset Fan Switch (60T12-610044)