47-22861-03 Rheem-Ruud L250F Limit Switch Manual Reset
47-22861-03 Rheem-Ruud L250F Limit Switch Manual Reset
The 47-22861-03 Rheem / Ruud Limit Switch is a genuine OEM manual reset high-limit safety control designed to protect heating equipment from excessive temperature conditions. Rated at L250°F, this limit switch interrupts the control circuit when temperatures exceed safe operating limits, helping prevent damage to the heat exchanger, burner assembly, and other critical system components. Unlike automatic reset controls, the 47-22861-03 requires manual resetting after a trip, providing an additional level of safety by requiring inspection of the overheating condition before restarting the system.
Manufactured to Rheem and Ruud specifications, this limit switch is an essential safety device for maintaining reliable furnace operation and protecting equipment from overheating-related failures.
Cross-Reference
- 47-22861-03
- 472286103
- Rheem 47-22861-03
- Ruud 47-22861-03
- L250F Limit Switch
- Manual Reset Limit Switch
- High Limit Safety Switch
Direct OEM
Yes – Genuine Rheem / Ruud OEM replacement limit switch.
Compatible Brands
- Rheem
- Ruud
- WeatherKing
- Richmond
Always verify compatibility using the equipment model and serial number before ordering.
Application
- Gas furnaces
- Heating systems
- High-limit safety circuits
- Over-temperature protection systems
- Residential HVAC equipment
- OEM furnace repairs
Related Components
- Rollout switches
- Pressure switches
- Flame sensors
- Ignitors
- Control boards
- Blower motors
- Air filters
- Heat exchangers
Technician Notes
- Temperature rating: L250°F.
- Manual reset safety design.
- Opens the circuit when excessive temperatures are detected.
- Reset button must be manually pressed after fault conditions are corrected.
- Repeated trips typically indicate airflow restrictions, blower problems, venting issues, dirty filters, or heat exchanger concerns.
- Always diagnose and correct the root cause of overheating before resetting or replacing the switch.
Common Symptoms of Failure
- Furnace shuts down on safety
- Open limit switch fault
- No heat condition
- Manual reset switch tripped
- Over-temperature error codes
- Intermittent heating operation
- Repeated safety shutdowns
- Limit circuit lockout
Installation Tips
- Disconnect electrical power before servicing.
- Verify the temperature rating matches the original switch.
- Inspect wiring terminals for signs of overheating.
- Install securely in the factory location.
- Check airflow and blower operation.
- Inspect the air filter and duct system.
- Restore power and test system operation.
- Verify proper temperature rise during operation.
Recommended Inspection Items
- Air filter condition
- Blower motor operation
- Heat exchanger condition
- Venting system
- Rollout switches
- Pressure switches
- Control board diagnostics
- Wiring terminals
- Furnace temperature rise
Rheem Protech 250F manual reset limit switch. Size 36TX16 with an elongated mounting bracket.
Also known as part # 472286103. This part will also replace the obsolete 3L02-250.