3L09-1 Copeland Comfort Control (White Rodgers) Board Mount Limit Control L140F
3L09-1 Copeland Comfort Control (White Rodgers) Board Mount Limit Control L140F
The 3L09-1 Board Mount Limit Control (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety switch designed to protect HVAC equipment, unit heaters, air handlers, and electrical control systems from overheating. Featuring a 140°F fixed open temperature and 100°F fixed close temperature, this open-on-rise bimetal limit switch interrupts the circuit when excessive temperatures are detected and automatically resets after cooling. Its compact board-mounted design with a 1.87-inch insertion length makes it ideal for OEM and replacement applications where space is limited.
Cross-Reference
- 3L09-1
- 3L091
- L140F
- 74T Series Limit Control
- White-Rodgers 3L09-1
- Copeland Comfort Control 3L09-1
Direct OEM
White-Rodgers 3L09-1
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Rheem
- Universal HVAC Applications
Application
Used in HVAC and heating equipment to:
- Protect electrical components from overheating
- Open the circuit at 140°F
- Automatically reset at 100°F
- Protect circuit boards and control compartments
- Prevent heat-related equipment damage
- Provide automatic temperature-based safety protection
Related Components
- Limit Switch
- Snap Disc Thermostat
- Fan Switch
- Furnace Control Board
- Blower Relay
- Transformer
- Temperature Sensor
- High Limit Control
- Safety Cutoff Switch
Technician Notes
The 3L09-1 is an automatic reset, open-on-rise board mount limit control utilizing a 1/2-inch bimetal snap disc with a 1.87-inch insertion length. Under normal conditions the contacts remain closed and open when the sensing surface reaches 140°F. The switch automatically resets when temperatures cool to approximately 100°F.
Its compact design makes it well suited for OEM HVAC equipment, fan coils, electrical enclosures, and control board protection applications where precise temperature monitoring is required.
Common Symptoms of Failure
- Equipment shuts down unexpectedly
- Open safety circuit fault
- Intermittent operation
- Repeated high-temperature trips
- Control board overheating faults
- No continuity through switch contacts
- Failure to reset properly
- Reduced equipment reliability
Installation Tips
- Disconnect power before servicing.
- Verify the replacement temperature ratings match the original control.
- Confirm switch action is Open on Rise.
- Ensure proper insertion depth and mounting position.
- Inspect terminals for corrosion or heat damage.
- Verify airflow around control compartments.
- Test continuity after installation.
- Confirm proper operation through a complete equipment cycle.
Recommended Inspection Items
- Control board condition
- Wiring connections
- Blower motor operation
- Airflow restrictions
- Electrical enclosure temperatures
- Transformer temperature
- Fan operation
- Terminal integrity
- Equipment ventilation
Controls, Temperature, 140 degrees F Fixed Open Temperature, 100 degrees F Fixed Close Temperature, Open on Rise Switch Action, Auto Reset, 1.87" Insertion Length, Board Mounted 1/2" Bimetal Disc Limit Switch