3L05-3 Copeland Comfort Control (White Rodgers), 210 to 250 degrees F Adjustable Temperature Diff
3L05-3 Copeland Comfort Control (White Rodgers), 210 to 250 degrees F Adjustable Temperature Diff
The 3L05-3 Adjustable Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed for HVAC, heating, commercial, and industrial equipment requiring adjustable high-temperature protection. Featuring an adjustable temperature range from 210°F to 250°F with a 40°F differential, this SPST open-on-rise switch interrupts the electrical circuit when temperatures exceed the selected setpoint and automatically resets after cooling.
Cross-Reference
- 3L05-3
- 3L053
- White-Rodgers 3L05-3
- Copeland Comfort Control 3L05-3
- 74T11 Series Adjustable Limit Switch
Direct OEM
White-Rodgers 3L05-3
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Rheem
- Universal HVAC Applications
- Commercial Heating Equipment
Application
Used in HVAC and heating equipment to:
- Provide adjustable overtemperature protection
- Open the circuit at a user-selected temperature between 210°F and 250°F
- Automatically reset after cooling by approximately 40°F
- Protect heat exchangers, electric heaters, motors, and control circuits
- Prevent equipment damage caused by excessive temperatures
- Support OEM and replacement service applications
Related Components
- Adjustable Limit Switch
- Snap Disc Thermostat
- High Limit Control
- Fan & Limit Control
- Furnace Control Board
- Blower Relay
- Transformer
- Temperature Sensor
- Safety Cutoff Switch
Technician Notes
The 3L05-3 is an automatic reset SPST limit switch with an adjustable operating range of 210°F to 250°F and a 40°F differential. The contacts remain closed during normal operation and open when the selected limit temperature is reached. Once the sensed temperature decreases approximately 40°F below the trip point, the contacts automatically reset and restore circuit operation.
This adjustable design is commonly used where specific overtemperature protection settings are required for OEM equipment, electric heat systems, and specialty heating applications.
Common Symptoms of Failure
- Frequent high-limit trips
- Equipment shuts down unexpectedly
- Open safety circuit faults
- Intermittent operation
- No continuity through switch contacts
- Heating system lockouts
- Failure to reset properly
- Temperature-related service calls
- Reduced equipment reliability
Installation Tips
- Disconnect power before servicing.
- Verify the required temperature setting before adjustment.
- Confirm switch action is Open on Rise.
- Set the desired cut-out temperature before installation.
- Mount securely to the original sensing location.
- Inspect terminals for corrosion or heat damage.
- Verify continuity and operation after installation.
- Test equipment through a complete operating cycle.
Recommended Inspection Items
- Blower motor operation
- Air filter condition
- Airflow restrictions
- Heat exchanger temperature
- Electric heater elements
- Wiring harness condition
- Electrical terminals
- Furnace control board
- Equipment temperature rise
Controls, Temperature, 210 to 250 degrees F Adjustable Temperature Range, 40 degrees F Differential Temperature, SPST Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (74T11-310712)