3L05-2 Copeland Comfort Control (White Rodgers), 175 to 215 F Adjustable Temperature Diff

  • $ 30.38
    Unit price per 
  • Save $ 8.51
Shipping calculated at checkout.


3L05-2 Copeland Comfort Control (White Rodgers), 175 to 215 F Adjustable Temperature Diff

The 3L05-2 Adjustable Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed for HVAC, heating, and refrigeration applications requiring adjustable overtemperature protection. Featuring an adjustable temperature range from 175°F to 215°F with a 40°F differential, this SPST open-on-rise switch interrupts the electrical circuit when temperatures exceed the selected setpoint and automatically resets after cooling.


Cross-Reference

  • 3L05-2
  • 3L052
  • White-Rodgers 3L05-2
  • Copeland Comfort Control 3L05-2
  • 74T11 Series Adjustable Limit Switch

Direct OEM

White-Rodgers 3L05-2


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • York
  • Coleman
  • Luxaire
  • Goodman
  • Rheem
  • Universal HVAC Applications

Application

Used in heating, cooling, and refrigeration equipment to:

  • Provide adjustable overtemperature protection
  • Open the circuit at a user-selected temperature between 175°F and 215°F
  • Automatically reset after cooling by approximately 40°F
  • Protect heat exchangers, motors, controls, and electrical components
  • Prevent equipment damage due to overheating
  • Support OEM and service replacement applications

Related Components

  • Adjustable Limit Switch
  • Snap Disc Thermostat
  • High Limit Control
  • Fan & Limit Control
  • Furnace Control Board
  • Blower Relay
  • Transformer
  • Temperature Sensor
  • Safety Cutoff Switch

Technician Notes

The 3L05-2 is an automatic reset SPST limit switch with an adjustable operating range of 175°F to 215°F and a 40°F differential. The contacts remain closed under normal operating conditions and open on temperature rise when the selected setpoint is reached. The switch automatically resets after the sensed temperature falls approximately 40°F below the trip point.

Always verify the required temperature setting before installation. Adjustable snap disc controls provide flexibility for OEM equipment and specialty heating applications where exact limit temperatures may vary.


Common Symptoms of Failure

  • Frequent high-limit trips
  • Equipment shuts down on safety
  • Intermittent heating operation
  • Open safety circuit faults
  • System lockouts
  • No continuity through switch contacts
  • Failure to reset properly
  • Reduced equipment reliability

Installation Tips

  1. Disconnect power before servicing.
  2. Verify the required temperature range before adjustment.
  3. Confirm switch action is Open on Rise.
  4. Set the desired temperature before installation.
  5. Mount securely to the original sensing location.
  6. Inspect wiring terminals for corrosion or heat damage.
  7. Verify continuity and operation after installation.
  8. Test the system through a complete operating cycle.

Recommended Inspection Items

  • Blower motor operation
  • Air filter condition
  • Heat exchanger temperature
  • Airflow restrictions
  • Supply and return duct condition
  • Electrical terminals
  • Wiring harness condition
  • Furnace control board
  • Equipment temperature rise

Controls, Temperature, 175 to 215 degrees F Adjustable Temperature Range, 40 degrees F Differential Temperature, SPST Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (74T11-310711)


We Also Recommend