3L05-13 Copeland Comfort Control (White Rodgers), 250 to 290F Adjustable Temperature
3L05-13 Copeland Comfort Control (White Rodgers), 250 to 290F Adjustable Temperature
The 3L05-13 Adjustable Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed for HVAC, heating, commercial, and industrial equipment requiring high-temperature overheat protection. Featuring an adjustable temperature range from 250°F to 290°F, this SPST open-on-rise limit switch interrupts the electrical circuit when temperatures exceed the selected setpoint and automatically resets after cooling, helping protect critical equipment from heat-related damage.
Cross-Reference
- 3L05-13
- 3L0513
- White-Rodgers 3L05-13
- Copeland Comfort Control 3L05-13
- 74T11 Series Adjustable Limit Switch
Direct OEM
White-Rodgers 3L05-13
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Rheem
- Universal HVAC Applications
- Commercial Heating Equipment
Application
Used in HVAC, heating, and industrial equipment to:
- Provide adjustable high-temperature protection
- Open the circuit at a user-selected temperature between 250°F and 290°F
- Automatically reset after cooling
- Protect electric heaters, heat exchangers, motors, and control circuits
- Prevent equipment damage due to overheating
- Support OEM and replacement service applications
Related Components
- Adjustable Limit Switch
- Snap Disc Thermostat
- High Limit Control
- Fan & Limit Control
- Furnace Control Board
- Blower Relay
- Transformer
- Temperature Sensor
- Safety Cutoff Switch
Technician Notes
The 3L05-13 is an automatic reset SPST limit switch with an adjustable operating range of 250°F to 290°F. The switch remains closed during normal operation and opens on temperature rise when the selected setpoint is reached. After temperatures fall below the reset threshold, the contacts automatically close and restore normal operation.
This control is commonly used in high-temperature HVAC, industrial heating, process equipment, and specialty heating applications where adjustable overtemperature protection is required.
Common Symptoms of Failure
- Equipment shuts down on high-limit fault
- Frequent temperature safety trips
- Open safety circuit
- Intermittent operation
- No continuity through switch contacts
- Failure to reset properly
- Equipment lockout conditions
- Reduced heating performance
- Nuisance shutdowns
Installation Tips
- Disconnect power before servicing.
- Verify the required temperature range before adjustment.
- Confirm switch action is Open on Rise.
- Set the desired operating temperature before installation.
- Mount securely to the original sensing surface.
- Inspect terminals for corrosion or heat damage.
- Verify continuity and operation after installation.
- Test equipment through a complete operating cycle.
Recommended Inspection Items
- Heater element condition
- Blower motor operation
- Airflow restrictions
- Heat exchanger condition
- Temperature rise across equipment
- Electrical terminals
- Wiring harness condition
- Control board operation
- Ventilation pathways
Controls, Temperature, 250 to 290 degrees F Adjustable Temperature Range, 40 degrees F Differential Temperature, SPST Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (74T11-310730)