3L05-10 Copeland Comfort Control (White Rodgers), 135 to 175F Adjustable Temperature Range

  • $ 30.38
    Unit price per 
  • Save $ 6.51
Shipping calculated at checkout.


3L05-10 Copeland Comfort Control (White Rodgers), 135 to 175F Adjustable Temperature Range

The 3L05-10 Adjustable Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed for HVAC, heating, and refrigeration equipment requiring adjustable overtemperature protection. Featuring an adjustable temperature range from 135°F to 175°F, this SPST open-on-rise limit switch interrupts the electrical circuit when temperatures exceed the selected setpoint and automatically resets after cooling, helping safeguard equipment from overheating.


Cross-Reference

  • 3L05-10
  • 3L0510
  • White-Rodgers 3L05-10
  • Copeland Comfort Control 3L05-10
  • 74T11 Series Adjustable Limit Switch

Direct OEM

White-Rodgers 3L05-10


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • York
  • Coleman
  • Luxaire
  • Goodman
  • Rheem
  • Universal HVAC Applications

Application

Used in HVAC and heating equipment to:

  • Provide adjustable overtemperature protection
  • Open the circuit at a user-selected temperature between 135°F and 175°F
  • Automatically reset after cooling
  • Protect heat exchangers, heaters, motors, and control circuits
  • Prevent equipment damage from excessive temperatures
  • Support OEM and replacement service applications

Related Components

  • Adjustable Limit Switch
  • Snap Disc Thermostat
  • High Limit Control
  • Fan & Limit Control
  • Furnace Control Board
  • Blower Relay
  • Transformer
  • Temperature Sensor
  • Safety Cutoff Switch

Technician Notes

The 3L05-10 is an automatic reset SPST limit switch featuring an adjustable operating range of 135°F to 175°F. The switch remains closed during normal operation and opens on temperature rise when the selected limit temperature is reached. Once the temperature falls below the reset point, the contacts automatically close, restoring normal operation.

Adjustable snap disc controls are commonly used where multiple OEM temperature settings may be required, reducing inventory while maintaining application flexibility.


Common Symptoms of Failure

  • Frequent high-limit trips
  • Equipment shuts down unexpectedly
  • Open safety circuit faults
  • Intermittent heating operation
  • No continuity through switch contacts
  • Furnace lockout conditions
  • Failure to reset properly
  • Reduced system reliability

Installation Tips

  1. Disconnect power before servicing.
  2. Verify the required temperature setting before adjustment.
  3. Confirm switch action is Open on Rise.
  4. Adjust the temperature setting as required by the equipment manufacturer.
  5. Mount securely to the original sensing surface.
  6. Inspect terminals for corrosion or overheating.
  7. Verify continuity and proper operation after installation.
  8. Test equipment through a complete operating cycle.

Recommended Inspection Items

  • Blower motor operation
  • Air filter condition
  • Heat exchanger temperature
  • Airflow restrictions
  • Supply and return ductwork
  • Electrical terminals
  • Wiring harness condition
  • Furnace control board
  • Equipment temperature rise

Controls, Temperature, 135 to 175 degrees F Adjustable Temperature Range, 20 degrees F Differential Temperature, SPST Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (74T11-310724)