3L05-1 Copeland Comfort Control (White Rodgers) 135 to 175 F Adjustable Temperature
3L05-1 Copeland Comfort Control (White Rodgers) 135 to 175 F Adjustable Temperature
The 3L05-1 Adjustable Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed for HVAC, heating, and equipment protection applications. Featuring an adjustable operating range from 135°F to 175°F with a 40°F differential, this SPST open-on-rise switch interrupts the electrical circuit when temperatures exceed the selected setpoint and automatically resets as temperatures decrease, providing reliable overtemperature protection.
Cross-Reference
- 3L05-1
- 3L051
- 74T11-310710
- White-Rodgers 3L05-1
- Copeland Comfort Control 3L05-1
Direct OEM
White-Rodgers 3L05-1
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Rheem
- Universal HVAC Applications
Application
Used in HVAC and heating equipment to:
- Provide adjustable overtemperature protection
- Open the circuit at a user-selected temperature from 135°F to 175°F
- Automatically reset after cooling by approximately 40°F
- Protect heat exchangers, motors, controls, and electrical components
- Prevent excessive operating temperatures
- Support OEM and replacement service applications
Related Components
- Adjustable Limit Switch
- Snap Disc Thermostat
- High Limit Control
- Fan & Limit Control
- Furnace Control Board
- Blower Relay
- Transformer
- Temperature Sensor
- Safety Cutoff Switch
Technician Notes
The 3L05-1 is an automatic reset SPST limit switch with an adjustable temperature range of 135°F to 175°F and a 40°F differential. The switch remains closed during normal operation and opens on temperature rise when the selected setpoint is reached. Once the temperature drops approximately 40°F below the cut-out temperature, the contacts automatically reset.
Always verify the desired temperature setting before installation. Adjustable controls offer greater application flexibility and are commonly used where OEM temperature requirements vary between equipment models.
Common Symptoms of Failure
- Equipment shuts down on temperature faults
- Intermittent operation
- Frequent high-limit trips
- No continuity through switch contacts
- Heating system lockouts
- Inconsistent operating temperatures
- Failure to reset properly
- Reduced equipment reliability
Installation Tips
- Disconnect power before servicing.
- Verify temperature range requirements before adjustment.
- Confirm switch action is Open on Rise.
- Set the desired temperature before installation.
- Mount securely to the original sensing location.
- Inspect terminals for overheating or corrosion.
- Verify continuity and operation after installation.
- Test system operation through a complete heating cycle.
Recommended Inspection Items
- Blower motor operation
- Air filter condition
- Heat exchanger temperature
- Airflow restrictions
- Supply and return ducts
- Electrical terminals
- Wiring harness condition
- Furnace control board
- Equipment temperature rise
Controls, Temperature, 135 to 175 degrees F Adjustable Temperature Range, 40 degrees F Differential Temperature, SPST Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (74T11-310710)