3L01-230 Copeland Comfort Control (White Rodgers) L230-40F

3L01-230 Copeland Comfort Control (White Rodgers) L230-40F

  • $ 14.95
    Unit price per 
  • Save $ 10.04
Shipping calculated at checkout.


3L01-230 Copeland Comfort Control (White Rodgers) L230-40F

The 3L01-230 Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed to protect HVAC, heating, and refrigeration equipment from excessive temperatures. Featuring a 230°F fixed cut-out temperature and a 40°F differential, this open-on-rise limit switch interrupts the electrical circuit when temperatures exceed safe operating limits and automatically resets after cooling, helping prevent damage to critical system components.


Cross-Reference

  • 3L01-230
  • 3L01230
  • L230-40F
  • 60T11 Series
  • White-Rodgers 3L01-230
  • Copeland Comfort Control 3L01-230

Direct OEM

White-Rodgers 3L01-230


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • York
  • Coleman
  • Luxaire
  • Goodman
  • Universal HVAC Applications
  • Refrigeration Equipment Manufacturers

Application

Used in HVAC and refrigeration equipment to:

  • Protect equipment from overheating
  • Open the control circuit at 230°F
  • Automatically reset after cooling
  • Protect compressors, heaters, motors, and control circuits
  • Prevent damage caused by excessive temperatures
  • Maintain safe equipment operation

Related Components

  • Snap Disc Limit Switch
  • High Limit Control
  • Fan Switch
  • Fan & Limit Control
  • Furnace Control Board
  • Blower Relay
  • Transformer
  • Temperature Sensor
  • Compressor Contactor

Technician Notes

The 3L01-230 is an automatic reset, open-on-rise snap disc limit switch. The contacts remain closed during normal operation and open when the sensing surface reaches 230°F. Once the temperature decreases by approximately 40°F, the contacts automatically reset and restore circuit operation.

Repeated limit trips frequently indicate restricted airflow, dirty coils, blocked vents, failing blower motors, excessive equipment temperatures, or improper system operation. Always identify and correct the root cause before replacing the switch.


Common Symptoms of Failure

  • Equipment shuts down on high temperature
  • Open limit circuit fault
  • Intermittent operation
  • Repeated safety trips
  • Furnace or HVAC lockout
  • No continuity through switch contacts
  • Failure to restart properly
  • Reduced system reliability

Installation Tips

  1. Disconnect electrical power before servicing.
  2. Verify temperature ratings match the original switch.
  3. Confirm switch action is "Open on Rise."
  4. Mount securely to the original sensing surface.
  5. Inspect terminals for heat damage or corrosion.
  6. Check airflow and operating temperatures.
  7. Verify continuity after installation.
  8. Test the unit through a complete operating cycle.

Recommended Inspection Items

  • Blower motor operation
  • Air filter condition
  • Coil cleanliness
  • Electrical terminals
  • Wiring harness condition
  • Control board diagnostics
  • Compressor operating temperatures
  • Supply voltage
  • Ventilation and airflow restrictions

 

Controls, Temperature, 190 degrees F Fixed Cut-in Temperature, 230 degrees F Fixed Cut-out Temperature, Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (60T11-610021)