colemanhvacparts.com, www.darindevries.com

3L01-150 Copeland Comfort Control (White Rodgers) LIMIT 110°F 150°F

  • $ 14.95
    Unit price per 
  • Save $ 10.04
Shipping calculated at checkout.


3L01-150 Copeland Comfort Control (White Rodgers) L150-40 LIMIT, IN110°F    OUT150°F

The 3L01-150 Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed to protect HVAC, heating, and refrigeration equipment from overheating. Featuring a 150°F fixed cut-out temperature and 110°F fixed cut-in temperature, this open-on-rise switch interrupts the electrical circuit when excessive temperatures occur and automatically resets after the temperature drops to a safe operating level.


Cross-Reference

  • 3L01-150
  • 3L01150
  • L150-40
  • 60T11-610009
  • White-Rodgers 3L01-150
  • Copeland Comfort Control 3L01-150

Direct OEM

White-Rodgers 3L01-150


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • York
  • Coleman
  • Luxaire
  • Universal HVAC Applications
  • Refrigeration Equipment

Application

Used in HVAC and refrigeration systems to:

  • Protect components from overheating
  • Open the circuit at 150°F
  • Automatically reset at 110°F
  • Protect motors, compressors, and control circuits
  • Prevent damage caused by excessive temperatures
  • Maintain safe equipment operation

Related Components

  • Snap Disc Limit Switch
  • High Limit Control
  • Fan Switch
  • Fan & Limit Control
  • Control Board
  • Transformer
  • Compressor Contactor
  • Temperature Sensor

Technician Notes

The 3L01-150 is an automatic reset, open-on-rise temperature limit switch. The contacts remain closed during normal operation and open when the sensed surface reaches 150°F. Once temperatures cool to approximately 110°F, the contacts automatically reset. Always match the switch action, mounting style, temperature ratings, and terminal configuration when replacing.

Repeated limit trips may indicate restricted airflow, dirty coils, failed blower motors, excessive equipment temperatures, or other system performance issues requiring diagnosis.


Common Symptoms of Failure

  • Equipment shuts down unexpectedly
  • Open safety circuit
  • Furnace or HVAC lockout conditions
  • Intermittent operation
  • No continuity through switch contacts
  • Repeated temperature safety trips
  • Compressor or heater protection faults
  • System fails to restart properly

Installation Tips

  1. Disconnect power before servicing.
  2. Verify the replacement temperature ratings match the original component.
  3. Confirm switch action is "Open on Rise."
  4. Mount securely to the designated sensing surface.
  5. Inspect wiring terminals for corrosion or heat damage.
  6. Check airflow and operating temperatures.
  7. Test continuity before returning the system to service.
  8. Verify complete system operation after installation.

Recommended Inspection Items

  • Blower motor operation
  • Airflow restrictions
  • Evaporator and condenser coils
  • Electrical terminals
  • Wiring harness condition
  • Control board diagnostics
  • Compressor operating temperatures
  • Supply voltage
  • Equipment ventilation

Controls, Temperature, 110 degrees F Fixed Cut-in Temperature, 150 degrees F Fixed Cut-out Temperature, Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (60T11-610009)