colemanhvacparts.com, www.darindevries.com

3L01-130 Copeland Comfort Control (White Rodgers) Limit 115F 130F

  • $ 14.95
    Unit price per 
  • Save $ 11.04
Shipping calculated at checkout.


3L01-130 Copeland Comfort Control (White Rodgers) Limit 115F 130F

he White-Rodgers 3L01-130 Snap Disc Limit Switch is an automatic reset temperature safety control designed to protect HVAC and heating equipment from overheating. Featuring a 130°F fixed cut-out temperature and 115°F fixed cut-in temperature, this open-on-rise switch interrupts the control circuit when temperatures exceed safe operating limits and automatically resets after the temperature decreases, ensuring reliable equipment protection and operation.


Cross-Reference

  • White-Rodgers 3L01-130
  • 3L01-130
  • 3L01130
  • 60T11 Series Limit Switch

Direct OEM

White-Rodgers 3L01-130


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • Universal HVAC Applications
  • OEM Heating Equipment
  • Refrigeration Equipment

Application

Used in heating and cooling equipment to:

  • Protect against overheating conditions
  • Open the control circuit at 130°F
  • Automatically reset at 115°F
  • Protect blower compartments and control circuits
  • Prevent component damage from excessive temperatures

Related Components

  • Limit Switch
  • Fan Switch
  • Fan & Limit Control
  • Furnace Control Board
  • Blower Relay
  • Transformer
  • Compressor Contactor
  • Temperature Control Switch

Technician Notes

The 3L01-130 is an automatic reset snap disc limit switch with open-on-rise operation. The switch contacts remain closed during normal operation and open when the sensing surface reaches 130°F. Once temperature falls to approximately 115°F, the contacts automatically reset. Always verify temperature ratings, switch action, mounting configuration, and terminal style prior to replacement.


Common Symptoms of Failure

  • Equipment shuts down unexpectedly
  • Intermittent operation
  • Open safety circuit
  • Heating system lockout
  • Blower control issues
  • No continuity through switch contacts
  • Nuisance temperature trips
  • Reduced equipment reliability

Installation Tips

  1. Disconnect power before servicing.
  2. Match the replacement temperature ratings exactly.
  3. Confirm switch action is "Open on Rise."
  4. Mount securely to the original sensing location.
  5. Inspect terminals for corrosion or heat damage.
  6. Check airflow and operating temperatures.
  7. Test switch continuity before startup.
  8. Verify complete system operation after installation.

Recommended Inspection Items

  • Air filter condition
  • Blower motor operation
  • Heat exchanger temperature
  • Coil cleanliness
  • Wiring connections
  • Control board diagnostics
  • Airflow restrictions
  • Electrical terminals
  • Venting system condition

Controls, Temperature, 115 degrees F Fixed Cut-in Temperature, 130 degrees F Fixed Cut-out Temperature, Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (60T11-610002)