3F01-180 Copeland Comfort Control (White Rodgers) F180-20F Fan Switch
3F01-180 Copeland Comfort Control (White Rodgers) F180-20F Fan Switch
The 3F01-180 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 180°F fixed cut-in temperature and a 20°F differential, this close-on-rise switch automatically energizes the blower when operating temperatures are reached and shuts the fan off during cooldown, promoting efficient airflow, improved comfort, and dependable system performance.
Cross-Reference
- 3F01-180
- 3F01180
- F180-20F
- White-Rodgers 3F01-180
- Copeland Comfort Control 3F01-180
- 60T12 Series Fan Switch
Direct OEM
White-Rodgers 3F01-180
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- Nordyne
- Intertherm
- Miller
- Coleman
- York
- Universal HVAC Applications
Application
Used in heating and HVAC equipment to:
- Control blower fan operation
- Close contacts at 180°F on temperature rise
- Open contacts after cooling by approximately 20°F
- Prevent circulation of cool air during startup
- Improve heating efficiency and comfort
- Automate blower operation based on plenum temperature
Related Components
- Fan Switch
- Fan & Limit Control
- High Limit Switch
- Blower Relay
- Furnace Control Board
- Blower Motor
- Transformer
- Thermostat
- Temperature Controls
Technician Notes
The 3F01-180 is an automatic reset, close-on-rise snap disc fan switch. Contacts remain open during lower temperatures and close when the sensing surface reaches 180°F, energizing the blower circuit. As the temperature drops approximately 20°F, the contacts automatically reopen, shutting the blower motor off.
Always verify temperature ratings, switch action, mounting style, and terminal configuration before replacement. Installing a fan switch with incorrect specifications can affect blower timing, comfort levels, and furnace performance.
Common Symptoms of Failure
- Blower fan will not start
- Blower runs continuously
- Delayed blower operation
- Poor warm-air delivery
- Furnace overheating
- Intermittent blower performance
- Short-cycling blower motor
- No continuity through switch contacts
Installation Tips
- Disconnect power before servicing.
- Verify replacement temperature ratings match the original switch.
- Confirm switch action is Close on Rise.
- Mount securely to the original sensing location.
- Inspect terminals for corrosion or overheating.
- Verify blower motor and relay operation.
- Test fan-on and fan-off temperatures after installation.
- Run a complete heating cycle to confirm proper operation.
Recommended Inspection Items
- Blower motor amperage
- Blower relay condition
- Air filter restriction
- Heat exchanger temperature
- Wiring terminals
- Furnace control board
- Temperature rise across furnace
- Supply and return airflow
- Blower wheel cleanliness
Controls, Temperature, 180 degrees F Fixed Cut-in Temperature, 160 degrees F Fixed Cut-out Temperature, Close on Rise Switch Action, Snap Disc Auto Reset Fan Switch (60T12-610065)