3F01-160 Copeland Comfort Control (White Rodgers) F160-20F Fan Switch
3F01-160 Copeland Comfort Control (White Rodgers) F160-20F Fan Switch
The 3F01-160 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 160°F fixed cut-in temperature and a 20°F differential, this close-on-rise switch automatically energizes the blower once the heat source reaches operating temperature and deactivates the fan during cooldown, helping improve comfort, efficiency, and equipment performance.
Cross-Reference
- 3F01-160
- 3F01160
- F160-20F
- White-Rodgers 3F01-160
- Copeland Comfort Control 3F01-160
- 60T12 Series Fan Switch
Direct OEM
White-Rodgers 3F01-160
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- Nordyne
- Intertherm
- Miller
- Coleman
- York
- Universal HVAC Applications
Application
Used in heating and HVAC equipment to:
- Control blower fan operation
- Close contacts at 160°F on temperature rise
- Open contacts after cooling by approximately 20°F
- Prevent circulation of cool air during startup
- Improve heating efficiency and occupant comfort
- Provide automatic fan cycling
Related Components
- Fan Switch
- Fan & Limit Control
- High Limit Switch
- Blower Relay
- Furnace Control Board
- Blower Motor
- Transformer
- Thermostat
- Temperature Controls
Technician Notes
The 3F01-160 is an automatic reset, close-on-rise snap disc fan switch. Contacts remain open during lower temperatures and close when the sensing surface reaches 160°F, energizing the blower circuit. When temperature drops by approximately 20°F, the contacts automatically reopen and shut the blower off.
Always verify switch action, mounting configuration, electrical ratings, and temperature specifications prior to replacement. Using the proper fan switch temperature rating is critical for maintaining proper blower timing and furnace performance.
Common Symptoms of Failure
- Blower fan will not start
- Blower runs continuously
- Delayed blower engagement
- Poor airflow during heating operation
- Furnace overheating
- Intermittent blower operation
- Short-cycling fan motor
- No continuity through switch contacts
Installation Tips
- Disconnect power before servicing.
- Verify replacement temperature ratings match the original switch.
- Confirm switch action is Close on Rise.
- Mount securely to the original sensing surface.
- Inspect terminals for corrosion or overheating.
- Verify blower motor operation before installation.
- Test fan-on and fan-off temperatures after replacement.
- Run a complete heating cycle to verify proper operation.
Recommended Inspection Items
- Blower motor amperage
- Blower relay operation
- Air filter condition
- Heat exchanger temperature
- Wiring terminals
- Furnace control board
- Temperature rise across furnace
- Supply and return airflow
- Blower wheel cleanliness
Controls, Temperature, 160 degrees F Fixed Cut-in Temperature, 140 degrees F Fixed Cut-out Temperature, Close on Rise Switch Action, Snap Disc Auto Reset Fan Switch (60T12-610064)