3F01-150 Copeland Comfort Control (White Rodgers) F150-20F Fan Switch

  • $ 14.95
    Unit price per 
  • Save $ 10.04
Shipping calculated at checkout.


3F01-150 Copeland Comfort Control (White Rodgers) F150-20F Fan Switch 

The 3F01-150 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 150°F fixed cut-in temperature and a 20°F differential, this close-on-rise fan switch automatically energizes the blower when operating temperatures are reached and shuts the fan off during cool-down, helping improve system efficiency, comfort, and equipment performance.


Cross-Reference

  • 3F01-150
  • 3F01150
  • F150-20F
  • White-Rodgers 3F01-150
  • Copeland Comfort Control 3F01-150
  • 60T12 Series Fan Switch

Direct OEM

White-Rodgers 3F01-150


Compatible Brands

  • White-Rodgers
  • Emerson
  • Copeland
  • Nordyne
  • Intertherm
  • Miller
  • Coleman
  • York
  • Universal HVAC Applications

Application

Used in heating and HVAC equipment to:

  • Control blower fan operation
  • Close contacts at 150°F on temperature rise
  • Open contacts after cooling by approximately 20°F
  • Prevent circulation of unheated air
  • Improve heating comfort and efficiency
  • Automate blower fan cycling

Related Components

  • Fan Switch
  • Fan & Limit Control
  • High Limit Switch
  • Blower Relay
  • Furnace Control Board
  • Blower Motor
  • Transformer
  • Thermostat
  • Temperature Controls

Technician Notes

The 3F01-150 is an automatic reset, close-on-rise snap disc fan switch. The contacts remain open during lower temperatures and close when the sensing surface reaches 150°F, energizing the blower motor circuit. Once temperature drops approximately 20°F, the contacts automatically reopen, shutting the blower off.

Always verify switch action, temperature ratings, mounting style, and terminal configuration before replacement. Using an incorrect fan switch temperature rating can affect blower performance, comfort levels, and furnace operation.


Common Symptoms of Failure

  • Blower fan will not start
  • Blower runs continuously
  • Delayed blower operation
  • Poor warm-air delivery
  • Furnace overheating
  • Intermittent blower operation
  • Short cycling blower motor
  • No continuity through switch contacts

Installation Tips

  1. Disconnect power before servicing.
  2. Verify replacement temperature ratings match the original.
  3. Confirm switch action is Close on Rise.
  4. Mount securely against the original sensing surface.
  5. Inspect terminals for corrosion or overheating.
  6. Verify blower motor operation before replacing the switch.
  7. Test fan-on and fan-off temperatures after installation.
  8. Run a complete heating cycle to confirm proper operation.

Recommended Inspection Items

  • Blower motor amperage
  • Blower relay operation
  • Air filter condition
  • Heat exchanger temperature
  • Wiring terminals
  • Furnace control board
  • Supply and return airflow
  • Temperature rise across furnace
  • Blower wheel cleanliness

Controls, Temperature, 150 degrees F Fixed Cut-in Temperature, 130 degrees F Fixed Cut-out Temperature, Close on Rise Switch Action, Snap Disc Auto Reset Fan Switch (60T12-610050)


We Also Recommend