3F01-140 Copeland Comfort Control (White Rodgers) F140-20F Fan Switch
3F01-140 Copeland Comfort Control (White Rodgers) F140-20F Fan Switch
The 3F01-140 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to manage blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 140°F fixed cut-in temperature and a 20°F differential, this close-on-rise switch automatically activates the blower when operating temperatures are reached and shuts the fan off as the system cools, helping improve comfort, efficiency, and equipment performance.
Cross-Reference
- 3F01-140
- 3F01140
- F140-20F
- White-Rodgers 3F01-140
- Copeland Comfort Control 3F01-140
- 60T12 Series Fan Switch
Direct OEM
White-Rodgers 3F01-140
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- Nordyne
- Intertherm
- Miller
- Coleman
- York
- Universal HVAC Applications
Application
Used in heating and HVAC equipment to:
- Control blower fan operation
- Close contacts at 140°F on temperature rise
- Open contacts after cooling by approximately 20°F
- Prevent circulation of cool air during startup
- Improve heating efficiency and comfort
- Automate blower fan cycling
Related Components
- Fan Switch
- Fan & Limit Control
- High Limit Switch
- Blower Relay
- Furnace Control Board
- Blower Motor
- Transformer
- Thermostat
- Temperature Controls
Technician Notes
The 3F01-140 is an automatic reset, close-on-rise snap disc fan switch. Contacts remain open during lower temperatures and close when the sensing surface reaches 140°F, energizing the blower circuit. As temperatures decrease approximately 20°F, the contacts automatically reopen, turning the blower off.
Always verify temperature ratings, switch action, terminal configuration, and mounting style before replacement. Improper fan switch ratings can affect blower timing, homeowner comfort, and overall furnace efficiency.
Common Symptoms of Failure
- Blower fan will not start
- Blower runs continuously
- Delayed blower operation
- Poor warm-air delivery
- Furnace overheating
- Short cycling blower motor
- Intermittent fan operation
- No continuity through switch contacts
Installation Tips
- Disconnect power before servicing.
- Verify replacement temperature ratings match the original switch.
- Confirm switch action is Close on Rise.
- Mount securely to the original sensing surface.
- Inspect terminals for corrosion or heat damage.
- Verify blower motor operation before replacing the switch.
- Confirm proper fan-on and fan-off temperatures after installation.
- Run a complete heating cycle to verify operation.
Recommended Inspection Items
- Blower motor amperage
- Blower relay condition
- Air filter restriction
- Heat exchanger temperature
- Wiring terminals
- Furnace control board
- Temperature rise across furnace
- Supply and return airflow
- Blower wheel cleanliness