3F01-130 Copeland Comfort Control (White Rodgers) F130-15
3F01-130 Copeland Comfort Control (White Rodgers) F130-15
The 3F01-130 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 130°F fixed cut-in temperature and a 15°F differential, this close-on-rise switch automatically energizes the blower when operating temperatures are reached and shuts the fan off as the system cools, helping improve comfort, efficiency, and equipment performance.
Cross-Reference
- 3F01-130
- 3F01130
- F130-15
- F130-15F
- White-Rodgers 3F01-130
- Copeland Comfort Control 3F01-130
Direct OEM
White-Rodgers 3F01-130
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- Nordyne
- Intertherm
- Miller
- Coleman
- York
- Universal HVAC Applications
Application
Used in heating and HVAC equipment to:
- Control blower fan operation
- Close contacts at 130°F on temperature rise
- Open contacts after cooling by approximately 15°F
- Prevent circulation of cool air during furnace startup
- Improve indoor comfort and heating efficiency
- Provide automatic blower fan cycling
Related Components
- Fan Switch
- Fan & Limit Control
- High Limit Switch
- Blower Relay
- Furnace Control Board
- Blower Motor
- Transformer
- Thermostat
- Temperature Controls
Technician Notes
The 3F01-130 is an automatic reset, close-on-rise snap disc fan switch. The contacts remain open during normal temperatures and close when the sensing surface reaches 130°F, energizing the blower circuit. As temperature falls approximately 15°F, the contacts automatically reopen, turning the blower off.
Always verify temperature ratings, switch action, terminal configuration, and mounting style before replacement. An incorrect fan switch temperature rating can affect comfort, blower timing, and furnace performance.
Common Symptoms of Failure
- Blower fan will not start
- Blower runs continuously
- Delayed fan operation
- Furnace overheating
- Short-cycling blower motor
- Poor warm-air delivery
- No continuity through switch contacts
- Inconsistent heating performance
Installation Tips
- Disconnect power before servicing.
- Verify replacement temperature ratings match the original switch.
- Confirm switch action is Close on Rise.
- Mount securely to the original sensing location.
- Inspect terminals for heat damage or corrosion.
- Check blower motor operation before installation.
- Verify fan-on and fan-off temperatures after replacement.
- Test the furnace through a complete heating cycle.
Recommended Inspection Items
- Blower motor operation
- Blower relay condition
- Air filter restriction
- Heat exchanger temperature
- Wiring terminals
- Control board operation
- Furnace temperature rise
- Supply and return airflow
- Blower wheel cleanliness
Controls, Temperature, 130 degrees F Fixed Cut-in Temperature, 115 degrees F Fixed Cut-out Temperature, Close on Rise Switch Action, Snap Disc Auto Reset Fan Switch (60T12-610047)