3F01-120 Copeland Comfort Control (White Rodgers) Fan Switch F120-10F
3F01-120 Copeland Comfort Control (White Rodgers) Fan Switch F120-10F
The 3F01-120 Snap Disc Fan Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature control designed to regulate blower fan operation in furnaces, air handlers, and HVAC equipment. Featuring a 120°F fixed cut-in temperature and a 10°F differential, this close-on-rise switch automatically energizes the blower when operating temperatures are reached and shuts the fan off as the system cools, improving comfort and system efficiency.
Cross-Reference
- 3F01-120
- 3F01120
- F120-10F
- White-Rodgers 3F01-120
- Copeland Comfort Control 3F01-120
- 60T12 Series Fan Switch
Direct OEM
White-Rodgers 3F01-120
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- Nordyne
- Intertherm
- Miller
- Coleman
- York
- Universal HVAC Applications
Application
Used in heating and HVAC equipment to:
- Control blower fan operation
- Close contacts at 120°F on temperature rise
- Open contacts after cooling by approximately 10°F
- Prevent circulation of cold air during startup
- Improve comfort and heating efficiency
- Provide automatic blower fan cycling
Related Components
- Fan Switch
- Fan & Limit Control
- High Limit Switch
- Blower Relay
- Furnace Control Board
- Blower Motor
- Transformer
- Thermostat
- Temperature Controls
Technician Notes
The 3F01-120 is an automatic reset, close-on-rise snap disc fan switch. The contacts remain open during normal temperatures and close when the sensing surface reaches 120°F, energizing the blower circuit. As temperature falls approximately 10°F, the contacts automatically reopen, shutting off the blower.
Always verify temperature ratings, switch action, mounting configuration, and wiring terminals match the original part before replacement.
Common Symptoms of Failure
- Blower fan will not start
- Blower fan runs continuously
- Delayed blower operation
- Poor airflow during heating
- Furnace overheating
- Short cycling blower motor
- No continuity through switch contacts
- Uneven heating performance
Installation Tips
- Disconnect power before servicing.
- Verify replacement temperature ratings match the original.
- Confirm switch action is "Close on Rise."
- Mount securely against the original sensing surface.
- Inspect wire terminals for corrosion or overheating.
- Test blower motor operation before condemning the switch.
- Verify fan-on and fan-off temperatures after installation.
- Run a complete heating cycle to confirm proper operation.
Recommended Inspection Items
- Blower motor operation
- Blower relay condition
- Air filter restriction
- Furnace temperature rise
- Heat exchanger condition
- Wiring terminals
- Furnace control board
- Supply and return airflow
- Blower wheel cleanliness
Fan control switch. F120-10F. Size T-O-D60T12. Switch closes at 120 degrees F and opens back up at 110 degrees F. Supco