{"product_id":"york-s1-025-37499-000-oem-flame-sensor","title":"York S1-025-37499-000 OEM Flame Sensor","description":"\u003ch1\u003eYork S1-025-37499-000 Description Flame Sensor. \u003cspan\u003eAlso known as part # 2438 OC4 0724\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eYork S1-025-37499-000 Flame Sensor\u003c\/strong\u003e is a direct OEM replacement flame sensing device designed to verify burner flame presence and ensure safe furnace operation. This critical safety component monitors the burner flame and signals the control board to keep the gas valve energized during normal heating operation. A faulty or contaminated flame sensor can cause ignition failure, burner shutdown, or intermittent heating issues. Also identified by marking \u003cstrong\u003e2438 OC4 0724\u003c\/strong\u003e. Backed by a \u003cstrong\u003e1-Year Warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross‑Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eS1-025-37499-000\u003c\/li\u003e\n\u003cli\u003eS102537499000\u003c\/li\u003e\n\u003cli\u003e2438 OC4 0724\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003eYes, Genuine OEM York Flame Sensor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify model and serial number compatibility before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas Furnaces\u003c\/li\u003e\n\u003cli\u003eResidential HVAC Systems\u003c\/li\u003e\n\u003cli\u003eFlame Proving and Burner Safety Circuits\u003c\/li\u003e\n\u003cli\u003eOEM Furnace Ignition Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHot Surface Ignitors (HSI)\u003c\/li\u003e\n\u003cli\u003eIntegrated Furnace Control Boards\u003c\/li\u003e\n\u003cli\u003ePressure Switches\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eRollout Switches\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eIgnition Wire Harnesses\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensors should be inspected whenever ignition issues occur.\u003c\/li\u003e\n\u003cli\u003eCarbon buildup on the sensor rod can prevent proper flame rectification.\u003c\/li\u003e\n\u003cli\u003eClean lightly with fine emery cloth or steel wool before replacement.\u003c\/li\u003e\n\u003cli\u003eReplace if cleaning does not restore reliable operation.\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding and flame signal strength during diagnosis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites then shuts off after a few seconds\u003c\/li\u003e\n\u003cli\u003eShort cycling during heating operation\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eNo heat complaints\u003c\/li\u003e\n\u003cli\u003eIgnition lockout conditions\u003c\/li\u003e\n\u003cli\u003eControl board flame-sense fault codes\u003c\/li\u003e\n\u003cli\u003eRepeated ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power to the furnace.\u003c\/li\u003e\n\u003cli\u003eLocate the flame sensor adjacent to the burner assembly.\u003c\/li\u003e\n\u003cli\u003eRemove the mounting screw and existing sensor.\u003c\/li\u003e\n\u003cli\u003eInspect wiring and mounting surface.\u003c\/li\u003e\n\u003cli\u003eInstall the new flame sensor securely.\u003c\/li\u003e\n\u003cli\u003eRestore power and test furnace operation.\u003c\/li\u003e\n\u003cli\u003eVerify consistent ignition and burner run time.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHot Surface Ignitor\u003c\/li\u003e\n\u003cli\u003eBurner Crossovers\u003c\/li\u003e\n\u003cli\u003eGround Connections\u003c\/li\u003e\n\u003cli\u003eControl Board Diagnostics\u003c\/li\u003e\n\u003cli\u003eGas Pressure\u003c\/li\u003e\n\u003cli\u003eBurner Flame Quality\u003c\/li\u003e\n\u003cli\u003eWiring Harness Connections\u003c\/li\u003e\n\u003cli\u003eAir Intake and Venting Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003e1 year warranty\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45561148178498,"sku":"S1-02537499000","price":69.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/s1-025-37499-000-3.jpg?v=1739521470","url":"https:\/\/hvacpartstoremarket.com\/products\/york-s1-025-37499-000-oem-flame-sensor","provider":"HVACpartstore","version":"1.0","type":"link"}