colemanhvacparts.com, www.darindevries.com

York S1-025-37499-000 OEM Flame Sensor

  • $ 69.61
    Unit price per 
  • Save $ 8.66
Shipping calculated at checkout.


York S1-025-37499-000 Description Flame Sensor. Also known as part # 2438 OC4 0724

The York S1-025-37499-000 Flame Sensor is a direct OEM replacement flame sensing device designed to verify burner flame presence and ensure safe furnace operation. This critical safety component monitors the burner flame and signals the control board to keep the gas valve energized during normal heating operation. A faulty or contaminated flame sensor can cause ignition failure, burner shutdown, or intermittent heating issues. Also identified by marking 2438 OC4 0724. Backed by a 1-Year Warranty.


Cross‑Reference

  • S1-025-37499-000
  • S102537499000
  • 2438 OC4 0724

Direct OEM

Yes, Genuine OEM York Flame Sensor.


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Fraser-Johnston

Verify model and serial number compatibility before ordering.


Application

  • Gas Furnaces
  • Residential HVAC Systems
  • Flame Proving and Burner Safety Circuits
  • OEM Furnace Ignition Systems

Related Components

  • Hot Surface Ignitors (HSI)
  • Integrated Furnace Control Boards
  • Pressure Switches
  • Gas Valves
  • Rollout Switches
  • Limit Switches
  • Ignition Wire Harnesses
  • Burner Assemblies

Technician Notes

  • Flame sensors should be inspected whenever ignition issues occur.
  • Carbon buildup on the sensor rod can prevent proper flame rectification.
  • Clean lightly with fine emery cloth or steel wool before replacement.
  • Replace if cleaning does not restore reliable operation.
  • Verify proper grounding and flame signal strength during diagnosis.

Common Symptoms of Failure

  • Furnace ignites then shuts off after a few seconds
  • Short cycling during heating operation
  • Intermittent burner operation
  • No heat complaints
  • Ignition lockout conditions
  • Control board flame-sense fault codes
  • Repeated ignition attempts

Installation Tips

  1. Disconnect power to the furnace.
  2. Locate the flame sensor adjacent to the burner assembly.
  3. Remove the mounting screw and existing sensor.
  4. Inspect wiring and mounting surface.
  5. Install the new flame sensor securely.
  6. Restore power and test furnace operation.
  7. Verify consistent ignition and burner run time.

Recommended Inspection Items

  • Hot Surface Ignitor
  • Burner Crossovers
  • Ground Connections
  • Control Board Diagnostics
  • Gas Pressure
  • Burner Flame Quality
  • Wiring Harness Connections
  • Air Intake and Venting Systems