{"product_id":"vr8305m3506-honeywell-hw-di-gas-valv","title":"VR8305M3506 Honeywell HW DI GAS VALV","description":"\u003ch1\u003eVR8305M3506 Honeywell HW DI GAS VALV\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003eVR8305M3506 and 393690-15 is the direct replacement for \u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eS1-2736-326P,\u003c\/span\u003e VR8450P6005\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eThe 393690-15 Flange Kit Bag Assembly, includes 3\/4\" Elbow Flange, O-Ring, 9\/64\" Hex Screws and 9\/64\" Hex Wrench, this is needed for the above replacement models\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/393690.png?v=1776288119\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eVR8305M3506 Honeywell Gas Valve\u003c\/strong\u003e is a 24-volt combination gas control valve designed for furnaces utilizing \u003cstrong\u003eDirect Ignition (DI), Hot Surface Ignition (HSI), and Intermittent Pilot ignition systems\u003c\/strong\u003e. Engineered for reliable gas flow control and dependable burner operation, this valve serves as a direct replacement for several OEM furnace gas valves used in residential and light commercial heating applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVR8305M3506\u003c\/strong\u003e and \u003cstrong\u003e393690-15 Flange Kit Assembly\u003c\/strong\u003e are the approved replacement combination for obsolete gas valve part numbers \u003cstrong\u003eS1-2736-326P\u003c\/strong\u003e and \u003cstrong\u003eVR8450P6005\u003c\/strong\u003e. For proper installation, the \u003cstrong\u003e393690-15 Flange Kit\u003c\/strong\u003e is required and includes the necessary mounting hardware and fittings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVR8305M3506\u003c\/li\u003e\n\u003cli\u003eHoneywell VR8305M3506\u003c\/li\u003e\n\u003cli\u003eS1-2736-326P\u003c\/li\u003e\n\u003cli\u003eVR8450P6005\u003c\/li\u003e\n\u003cli\u003e393690-15\u003c\/li\u003e\n\u003cli\u003eYork S1-2736-326P\u003c\/li\u003e\n\u003cli\u003eHoneywell Universal Gas Valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Honeywell Replacement Gas Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDirect replacement for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eS1-2736-326P\u003c\/li\u003e\n\u003cli\u003eVR8450P6005\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRequires:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e393690-15 Flange Kit Assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eHoneywell-equipped gas furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify furnace model and valve specifications before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eDirect Ignition systems\u003c\/li\u003e\n\u003cli\u003eHot Surface Ignition (HSI) furnaces\u003c\/li\u003e\n\u003cli\u003eIntermittent Pilot ignition systems\u003c\/li\u003e\n\u003cli\u003eResidential HVAC equipment\u003c\/li\u003e\n\u003cli\u003eReplacement gas valve installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e393690-15 Flange Kit Assembly\u003c\/li\u003e\n\u003cli\u003eHot surface ignitors\u003c\/li\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003eIgnition control boards\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003eBurner assemblies\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e24 VAC operation.\u003c\/li\u003e\n\u003cli\u003eCompatible with Direct Ignition, HSI, and Intermittent Pilot systems.\u003c\/li\u003e\n\u003cli\u003eReplaces obsolete S1-2736-326P and VR8450P6005 valves.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e393690-15 Flange Kit is required for installation.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eVerify gas type and manifold pressure after installation.\u003c\/li\u003e\n\u003cli\u003eLeak test all gas piping connections prior to placing equipment back into service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e393690-15 Flange Kit Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4\" Elbow Flange\u003c\/li\u003e\n\u003cli\u003eO-Ring\u003c\/li\u003e\n\u003cli\u003e(2) 9\/64\" Hex Screws\u003c\/li\u003e\n\u003cli\u003e9\/64\" Hex Wrench\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo gas flow to burners\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eGas valve fails to open\u003c\/li\u003e\n\u003cli\u003eIgnition lockout faults\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eFurnace cycles without burner ignition\u003c\/li\u003e\n\u003cli\u003eInconsistent burner performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power and gas supply.\u003c\/li\u003e\n\u003cli\u003eConfirm part number compatibility before replacement.\u003c\/li\u003e\n\u003cli\u003eInstall the required 393690-15 flange kit.\u003c\/li\u003e\n\u003cli\u003eVerify proper valve orientation and gas flow direction.\u003c\/li\u003e\n\u003cli\u003eReconnect wiring according to factory specifications.\u003c\/li\u003e\n\u003cli\u003eLeak test all fittings and connections.\u003c\/li\u003e\n\u003cli\u003eVerify manifold pressure settings.\u003c\/li\u003e\n\u003cli\u003eConfirm proper ignition and burner operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIgnitor condition\u003c\/li\u003e\n\u003cli\u003eFlame sensor cleanliness\u003c\/li\u003e\n\u003cli\u003eGas manifold pressure\u003c\/li\u003e\n\u003cli\u003eBurner assembly\u003c\/li\u003e\n\u003cli\u003eControl board operation\u003c\/li\u003e\n\u003cli\u003ePressure switch functionality\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003cli\u003eHeat exchanger inspection\u003c\/li\u003e\n\u003cli\u003eGas supply pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45561110626370,"sku":"VR8305M3506","price":277.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/41kP-ougMQL._SX342.jpg?v=1739519264","url":"https:\/\/hvacpartstoremarket.com\/products\/vr8305m3506-honeywell-hw-di-gas-valv","provider":"HVACpartstore","version":"1.0","type":"link"}