{"product_id":"uibl-dinosaur-12v-long-board-w-spade-39-0410","title":"UIBL DINOSAUR 12V LONG BOARD W\/SPADE 39-0410","description":"\u003ch1\u003eUIBL DINOSAUR 12V LONG BOARD W\/SPADE 39-0410\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eUIBL Dinosaur Electronics Long Board\u003c\/strong\u003e is a premium universal \u003cstrong\u003e12-volt DC ignition control board\u003c\/strong\u003e designed specifically for RV furnaces and mobile heating applications. Identified by part number \u003cstrong\u003e39-0410\u003c\/strong\u003e, this long-board configuration features \u003cstrong\u003espade terminal connections\u003c\/strong\u003e for straightforward installation and compatibility with a wide range of RV furnace systems.\u003c\/p\u003e\n\u003cp\u003eManufactured in the USA by \u003cstrong\u003eDinosaur Electronics\u003c\/strong\u003e, the UIBL is engineered to replace numerous OEM ignition boards while providing enhanced reliability, improved diagnostics, and durable construction. The board manages ignition sequencing, flame sensing, safety lockout functions, and furnace burner operation, making it a dependable replacement solution for failed RV furnace control modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUIBL\u003c\/li\u003e\n\u003cli\u003e39-0410\u003c\/li\u003e\n\u003cli\u003eDinosaur UIBL\u003c\/li\u003e\n\u003cli\u003eDinosaur Electronics 39-0410\u003c\/li\u003e\n\u003cli\u003eUniversal Ignition Board Long\u003c\/li\u003e\n\u003cli\u003eRV Furnace Ignition Board\u003c\/li\u003e\n\u003cli\u003e12V Ignition Control Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect Replacement\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal replacement ignition board\u003c\/strong\u003e for many compatible RV furnace applications.\u003c\/p\u003e\n\u003cp\u003eAlways verify furnace model, board configuration, and terminal layout before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eCompatible with many RV furnace applications including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAtwood\u003c\/li\u003e\n\u003cli\u003eHydro Flame\u003c\/li\u003e\n\u003cli\u003eDometic\u003c\/li\u003e\n\u003cli\u003eSuburban\u003c\/li\u003e\n\u003cli\u003eDuo-Therm\u003c\/li\u003e\n\u003cli\u003eOther compatible 12V RV furnace systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify compatibility before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRV furnaces\u003c\/li\u003e\n\u003cli\u003eTravel trailer heating systems\u003c\/li\u003e\n\u003cli\u003eFifth wheel furnace systems\u003c\/li\u003e\n\u003cli\u003eMotorhome furnaces\u003c\/li\u003e\n\u003cli\u003eMobile heating equipment\u003c\/li\u003e\n\u003cli\u003e12V ignition control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003eIgniters\u003c\/li\u003e\n\u003cli\u003eSail switches\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003eBlower motors\u003c\/li\u003e\n\u003cli\u003eGas valves\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003cli\u003eWiring harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Dinosaur Electronics replacement board.\u003c\/li\u003e\n\u003cli\u003e12 VDC operation.\u003c\/li\u003e\n\u003cli\u003eLong-board design.\u003c\/li\u003e\n\u003cli\u003eSpade terminal connections.\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for RV furnace applications.\u003c\/li\u003e\n\u003cli\u003eKnown for enhanced reliability compared to many original boards.\u003c\/li\u003e\n\u003cli\u003eVerify grounding and supply voltage before replacing the control board.\u003c\/li\u003e\n\u003cli\u003eInspect igniter, sail switch, and gas valve operation if ignition issues are present.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo heat operation\u003c\/li\u003e\n\u003cli\u003eIgnition lockout conditions\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eBlower runs without burner ignition\u003c\/li\u003e\n\u003cli\u003eNo response to thermostat calls\u003c\/li\u003e\n\u003cli\u003eFlame sensing failures\u003c\/li\u003e\n\u003cli\u003eBurned or damaged board components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect 12V DC power before servicing.\u003c\/li\u003e\n\u003cli\u003eLabel all wiring connections before removal.\u003c\/li\u003e\n\u003cli\u003eVerify board compatibility with the furnace model.\u003c\/li\u003e\n\u003cli\u003eTransfer wiring to corresponding terminals.\u003c\/li\u003e\n\u003cli\u003eInspect all connectors for corrosion or heat damage.\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding.\u003c\/li\u003e\n\u003cli\u003eRestore power and test furnace operation.\u003c\/li\u003e\n\u003cli\u003eConfirm proper ignition and safety shutdown functions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSail switch operation\u003c\/li\u003e\n\u003cli\u003eIgniter condition\u003c\/li\u003e\n\u003cli\u003eFlame sensor circuit\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eBlower motor performance\u003c\/li\u003e\n\u003cli\u003eThermostat wiring\u003c\/li\u003e\n\u003cli\u003eGround connections\u003c\/li\u003e\n\u003cli\u003eFurnace heat exchanger\u003c\/li\u003e\n\u003cli\u003e12V power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":46136168054850,"sku":"UIBL","price":149.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-22231725.png?v=1795414658","url":"https:\/\/hvacpartstoremarket.com\/products\/uibl-dinosaur-12v-long-board-w-spade-39-0410","provider":"HVACpartstore","version":"1.0","type":"link"}