colemanhvacparts.com, www.darindevries.com

UIBL DINOSAUR 12V LONG BOARD W/SPADE 39-0410

  • $ 149.95
    Unit price per 
  • Save $ 39.83
Shipping calculated at checkout.


UIBL DINOSAUR 12V LONG BOARD W/SPADE 39-0410

The UIBL Dinosaur Electronics Long Board is a premium universal 12-volt DC ignition control board designed specifically for RV furnaces and mobile heating applications. Identified by part number 39-0410, this long-board configuration features spade terminal connections for straightforward installation and compatibility with a wide range of RV furnace systems.

Manufactured in the USA by Dinosaur Electronics, the UIBL is engineered to replace numerous OEM ignition boards while providing enhanced reliability, improved diagnostics, and durable construction. The board manages ignition sequencing, flame sensing, safety lockout functions, and furnace burner operation, making it a dependable replacement solution for failed RV furnace control modules.


Cross-Reference

  • UIBL
  • 39-0410
  • Dinosaur UIBL
  • Dinosaur Electronics 39-0410
  • Universal Ignition Board Long
  • RV Furnace Ignition Board
  • 12V Ignition Control Board

Direct Replacement

Universal replacement ignition board for many compatible RV furnace applications.

Always verify furnace model, board configuration, and terminal layout before installation.


Compatible Brands

Compatible with many RV furnace applications including:

  • Atwood
  • Hydro Flame
  • Dometic
  • Suburban
  • Duo-Therm
  • Other compatible 12V RV furnace systems

Verify compatibility before ordering.


Application

  • RV furnaces
  • Travel trailer heating systems
  • Fifth wheel furnace systems
  • Motorhome furnaces
  • Mobile heating equipment
  • 12V ignition control applications

Related Components

  • Flame sensors
  • Igniters
  • Sail switches
  • Limit switches
  • Blower motors
  • Gas valves
  • Thermostats
  • Wiring harnesses

Technician Notes

  • Genuine Dinosaur Electronics replacement board.
  • 12 VDC operation.
  • Long-board design.
  • Spade terminal connections.
  • Designed specifically for RV furnace applications.
  • Known for enhanced reliability compared to many original boards.
  • Verify grounding and supply voltage before replacing the control board.
  • Inspect igniter, sail switch, and gas valve operation if ignition issues are present.

Common Symptoms of Failure

  • Furnace will not ignite
  • No heat operation
  • Ignition lockout conditions
  • Intermittent furnace operation
  • Blower runs without burner ignition
  • No response to thermostat calls
  • Flame sensing failures
  • Burned or damaged board components

Installation Tips

  1. Disconnect 12V DC power before servicing.
  2. Label all wiring connections before removal.
  3. Verify board compatibility with the furnace model.
  4. Transfer wiring to corresponding terminals.
  5. Inspect all connectors for corrosion or heat damage.
  6. Verify proper grounding.
  7. Restore power and test furnace operation.
  8. Confirm proper ignition and safety shutdown functions.

Recommended Inspection Items

  • Sail switch operation
  • Igniter condition
  • Flame sensor circuit
  • Gas valve operation
  • Blower motor performance
  • Thermostat wiring
  • Ground connections
  • Furnace heat exchanger
  • 12V power supply