colemanhvacparts.com, www.darindevries.com

S1-7680-3791 , L140-30 LIMIT Snap Disc Limit Control Switch

  • $ 34.78
    Unit price per 
  • Save $ 4.74
Shipping calculated at checkout.


The S1-7680-3791 L140-30 Snap Disc Limit Control Switch is a genuine OEM temperature safety control designed to protect HVAC equipment from overheating conditions. Rated at L140-30, this automatic reset snap disc limit switch opens the circuit when temperatures reach approximately 140°F and resets after the temperature drops by approximately 30°F. Commonly used in furnaces, air handlers, and heating applications, this safety device helps prevent excessive temperatures that could damage equipment components or affect system performance.


Cross-Reference

  • S1-7680-3791
  • 7680-3791
  • S176803791
  • L140-30
  • Snap Disc Limit Switch
  • Limit Control Switch

Direct OEM

Yes – Genuine York/Coleman OEM replacement limit switch.


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Fraser-Johnston
  • Evcon

Application

  • Gas furnaces
  • Electric furnaces
  • Air handlers
  • Heating equipment safety controls
  • Temperature monitoring circuits
  • Blower compartment temperature protection

Related Components

  • High limit switches
  • Rollout switches
  • Fan controls
  • Heat sequencers
  • Blower motors
  • Control boards
  • Pressure switches
  • Temperature sensors

Technician Notes

  • L140-30 temperature rating.
  • Automatic reset design.
  • Opens on temperature rise.
  • Critical safety component for over-temperature protection.
  • Always investigate and correct the cause of overheating before replacing a failed limit switch.
  • Verify mounting configuration and terminal style before installation.

Common Symptoms of Failure

  • Furnace will not heat
  • Intermittent heating operation
  • Open limit fault codes
  • Blower operating without heat
  • Frequent safety shutdowns
  • Nuisance limit trips
  • Equipment lockout conditions

Installation Tips

  1. Disconnect power before servicing.
  2. Verify replacement temperature rating matches the original switch.
  3. Inspect terminals for corrosion or heat damage.
  4. Mount securely against the designated sensing surface.
  5. Transfer wires carefully to the correct terminals.
  6. Check airflow and filter condition before startup.
  7. Verify normal equipment operation after installation.

Recommended Inspection Items

  • Air filter condition
  • Blower motor operation
  • Blower wheel cleanliness
  • Supply and return airflow
  • Heat exchanger area
  • Venting system
  • Wiring terminals
  • Control board operation
  • Temperature rise through the furnace

We Also Recommend