{"product_id":"s1-7680-3591-coleman-limit-switch-l155-20f","title":"S1-7680-3591 Coleman limit switch L155-20F","description":"\u003ch1\u003e\u003cspan\u003eS1-7680-3591 Coleman limit switch L155-20F \u003c\/span\u003e\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eS1‑7680‑3591\u003c\/strong\u003e is a genuine OEM \u003cstrong\u003eL155‑20F automatic reset limit switch\u003c\/strong\u003e designed for Coleman, York, Luxaire, Fraser‑Johnston, and Evcon furnace applications. This temperature‑sensitive safety control protects the furnace from overheating by opening the control circuit when temperatures reach \u003cstrong\u003e155°F\u003c\/strong\u003e and automatically resetting after the temperature falls approximately \u003cstrong\u003e20°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eInstalled in the furnace heat compartment, the S1‑7680‑3591 helps prevent damage to the heat exchanger, blower components, wiring, and surrounding furnace parts caused by excessive operating temperatures. Built to original Source 1 specifications, this limit switch ensures proper temperature protection and reliable furnace operation.\u003c\/p\u003e\n\u003cp\u003eIdeal for replacing failed or nuisance‑tripping limit switches while maintaining OEM safety standards.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e Cross‑Reference \u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDirect OEM\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eS1‑7680‑3591\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e7680‑3591\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eYork Source 1 OEM Limit Switch\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser‑Johnston\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e L155‑20F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Temperature:\u003c\/strong\u003e 155°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential:\u003c\/strong\u003e 20°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Type:\u003c\/strong\u003e Automatic Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e High‑Limit Safety Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Limit Switches\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e(Verify temperature ratings before substitution)\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eS1‑025‑35380‑000 — L140‑30F\u003c\/li\u003e\n\u003cli\u003eS1‑025‑22273‑001 — L150‑110F Fork Limit\u003c\/li\u003e\n\u003cli\u003e7624A3591 — L180F Upper Limit\u003c\/li\u003e\n\u003cli\u003eS1‑025‑29041‑007 — L170‑30F\u003c\/li\u003e\n\u003cli\u003eS1‑025‑31813‑000 — L160‑30F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e Technician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProtects furnace components from excessive temperatures.\u003c\/li\u003e\n\u003cli\u003eAutomatically resets after cooldown.\u003c\/li\u003e\n\u003cli\u003eCommon causes of limit trips include:\n\u003cul\u003e\n\u003cli\u003eDirty air filters\u003c\/li\u003e\n\u003cli\u003eRestricted airflow\u003c\/li\u003e\n\u003cli\u003eFailing blower motor\u003c\/li\u003e\n\u003cli\u003eBlocked evaporator coil\u003c\/li\u003e\n\u003cli\u003eClosed supply registers\u003c\/li\u003e\n\u003cli\u003eDuct restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace burner shuts off before satisfying thermostat\u003c\/li\u003e\n\u003cli\u003eBlower continues running after burner shutdown\u003c\/li\u003e\n\u003cli\u003eOpen limit fault conditions\u003c\/li\u003e\n\u003cli\u003eIntermittent heating\u003c\/li\u003e\n\u003cli\u003eHeater overheating shutdowns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCross Reference\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 100.082%; height: 78.4px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 24.898%; height: 19.6px;\"\u003eEquivalent P\/N\u003c\/th\u003e\n\u003cth style=\"width: 72.2449%; height: 19.6px;\"\u003eManufacturer \/ Notes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.898%; height: 19.6px;\"\u003e7680-359\u003c\/td\u003e\n\u003ctd style=\"width: 72.2449%; height: 19.6px;\"\u003eOriginal Coleman P\/N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.898%; height: 19.6px;\"\u003e626440\u003c\/td\u003e\n\u003ctd style=\"width: 72.2449%; height: 19.6px;\"\u003eNordyne upper limit switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.898%; height: 19.6px;\"\u003eL155-20F\u003c\/td\u003e\n\u003ctd style=\"width: 72.2449%; height: 19.6px;\"\u003eUniversal limit switch designation (60T11 style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways disconnect electrical power at the service panel before servicing the furnace.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess the limit switch through the blower compartment; remove mounting screws and gently pull the switch out of its 60T11 housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify continuity across the L1 and L2 terminals at room temperature and an open circuit when heated above 155 °F.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure replacement switch is fully seated in the housing and terminals are snug—loose connections can overheat.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, run the furnace through several heat cycles to confirm proper trip and reset operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eModels \/ Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eColeman Gas Furnaces\u003c\/td\u003e\n\u003ctd\u003e7600, 7624, 7654, 7680 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYork \u0026amp; Miller Furnaces\u003c\/td\u003e\n\u003ctd\u003eUniversal 60T11 limit housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftermarket Retrofits\u003c\/td\u003e\n\u003ctd\u003eAny 60T11-style upper limit switch mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNordyne \/ Broan-NuTone\u003c\/td\u003e\n\u003ctd\u003eReplacement for part 626440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUpper limit switch shuts down gas valve if overheating occurs. L155-20F. Size 60T11.\u003c\/p\u003e\n\u003cp\u003eReplaces 7680-359. Also replaces Nordyne part # 626440. \u003c\/p\u003e\n\u003ch3 id=\"part-num\"\u003eS1-7680-3591\u003c\/h3\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13114302211,"sku":"7680-3591","price":37.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot_2026-10-25_111553.png?v=1792952192","url":"https:\/\/hvacpartstoremarket.com\/products\/s1-7680-3591-coleman-limit-switch-l155-20f","provider":"HVACpartstore","version":"1.0","type":"link"}