{"product_id":"s1-7670-3451-coleman-foam-filter-clips-sold-as-pair-oem","title":"S1-7670-3451 Coleman Foam Filter Clips (sold as pair) OEM","description":"\u003ch2\u003eS1-7670-3451 Coleman Foam Filter Clips (sold as pair) OEM 7670-3451\u003c\/h2\u003e\n\u003ch4\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/h4\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eS1-7670-3451 Foam Filter Clips\u003c\/strong\u003e are genuine Coleman OEM filter retainers designed to securely hold the foam furnace filter in place within the furnace front access panel. These clips help maintain proper filter positioning, ensuring correct airflow and preventing filter movement during furnace operation. Sold as a \u003cstrong\u003epair (2 clips per package)\u003c\/strong\u003e, these retainers are the direct replacement for worn, damaged, or missing filter clips used with the \u003cstrong\u003eS1-7660-3401 foam filter\u003c\/strong\u003e (sold separately).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eS1-7670-3451\u003c\/li\u003e\n\u003cli\u003e7670-3451\u003c\/li\u003e\n\u003cli\u003eL87-803\u003c\/li\u003e\n\u003cli\u003eS1-3300-3861\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine Coleman OEM replacement filter clips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMobile home furnaces\u003c\/li\u003e\n\u003cli\u003eManufactured housing furnaces\u003c\/li\u003e\n\u003cli\u003eFurnace front panel filter retention\u003c\/li\u003e\n\u003cli\u003eFoam filter mounting systems\u003c\/li\u003e\n\u003cli\u003eReplacement filter retaining clips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsed with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS1-7660-3401 Foam Filter\u003c\/strong\u003e (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eS1-7660-3401 Foam Filter\u003c\/li\u003e\n\u003cli\u003eFurnace access panels\u003c\/li\u003e\n\u003cli\u003eFilter racks\u003c\/li\u003e\n\u003cli\u003eFilter doors\u003c\/li\u003e\n\u003cli\u003eReturn air assemblies\u003c\/li\u003e\n\u003cli\u003eFurnace cabinet hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSold as a pair (2 clips).\u003c\/li\u003e\n\u003cli\u003eDesigned to retain the foam filter inside the furnace front panel.\u003c\/li\u003e\n\u003cli\u003eInspect filter rack and panel mounting points for damage during replacement.\u003c\/li\u003e\n\u003cli\u003eReplace missing clips immediately to prevent filter movement and bypass airflow.\u003c\/li\u003e\n\u003cli\u003eVerify foam filter condition whenever clips are serviced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFoam filter falls out of position\u003c\/li\u003e\n\u003cli\u003eFilter not secured in front panel\u003c\/li\u003e\n\u003cli\u003eExcessive dust accumulation inside furnace\u003c\/li\u003e\n\u003cli\u003eAir bypass around filter\u003c\/li\u003e\n\u003cli\u003eMissing or broken filter retainers\u003c\/li\u003e\n\u003cli\u003eFilter vibration or movement during operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eTurn off power to the furnace.\u003c\/li\u003e\n\u003cli\u003eRemove the front access panel.\u003c\/li\u003e\n\u003cli\u003eInspect the existing filter and retaining clips.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement clips in the original mounting locations.\u003c\/li\u003e\n\u003cli\u003eVerify the foam filter is held securely.\u003c\/li\u003e\n\u003cli\u003eReinstall the access panel.\u003c\/li\u003e\n\u003cli\u003eConfirm unrestricted airflow through the filter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eS1-7660-3401 foam filter condition\u003c\/li\u003e\n\u003cli\u003eFilter rack integrity\u003c\/li\u003e\n\u003cli\u003eFurnace front panel condition\u003c\/li\u003e\n\u003cli\u003eReturn air openings\u003c\/li\u003e\n\u003cli\u003eDust accumulation inside cabinet\u003c\/li\u003e\n\u003cli\u003eAirflow restrictions\u003c\/li\u003e\n\u003cli\u003eCabinet seals and gaskets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45563821228098,"sku":"7670-3451","price":54.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_210088366.jpeg?v=1566073494","url":"https:\/\/hvacpartstoremarket.com\/products\/s1-7670-3451-coleman-foam-filter-clips-sold-as-pair-oem","provider":"HVACpartstore","version":"1.0","type":"link"}