colemanhvacparts.com, www.darindevries.com

S1-6HK16502006 York 20kw Electric Heat Kit with Breakers

  • $ 596.48
    Unit price per 
  • Save $ 38.97
Shipping calculated at checkout.


S1-6HK16502006 York 20kw Electric Heat Kit with Breakers

The York S1-6HK16502006 Electric Heat Kit is a 20 kW OEM electric heater assembly with integrated circuit breakers, engineered for compatible York, Coleman, and Luxaire air handlers. This factory-authorized heat strip kit delivers high-capacity auxiliary and emergency heating while providing built-in overcurrent protection for reliable and safe HVAC system operation.


Cross-Reference

  • York S1-6HK16502006
  • S1-6HK16502006
  • 6HK16502006
  • HK16502006

Direct OEM

York S1-6HK16502006


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Johnson Controls

Application

Used in compatible air handlers and heat pump systems to:

  • Provide 20 kW electric heating capacity
  • Deliver auxiliary heat during peak heating demand
  • Supply emergency heat operation
  • Support residential and light commercial HVAC systems
  • Enhance heat pump performance during extremely cold conditions

Related Components

  • Electric Heat Strip
  • Circuit Breaker Assembly
  • Heat Sequencer
  • High-Limit Switch
  • Air Handler Control Board
  • Transformer
  • Contactor
  • Thermostat
  • Blower Motor Assembly

Technician Notes

The S1-6HK16502006 is a factory-engineered 20 kW electric heater package featuring integrated circuit breakers for equipment protection and simplified installation. Verify air handler compatibility, voltage requirements, and branch circuit sizing before installation. Proper airflow and blower operation are essential to prevent overheating and nuisance high-limit trips.


Common Symptoms of Failure

  • No auxiliary heat
  • No emergency heat operation
  • Repeated circuit breaker trips
  • Open heating elements
  • High-limit switch activation
  • Reduced heating output
  • Heater fails to energize
  • Burned wire terminals
  • Uneven supply air temperatures
  • Intermittent heating performance

Installation Tips

  1. Disconnect all power before servicing.
  2. Verify compatibility with the air handler model.
  3. Confirm supply voltage and circuit capacity requirements.
  4. Inspect breaker and wiring connections.
  5. Check element resistance before energizing.
  6. Verify sequencer and safety control operation.
  7. Measure operating amperage after installation.
  8. Test auxiliary and emergency heat functions.
  9. Confirm adequate airflow across the heater assembly.

Recommended Inspection Items

  • Heating elements
  • Integrated circuit breakers
  • Heat sequencers
  • High-limit switches
  • Electrical terminals
  • Supply voltage
  • Blower motor performance
  • Control board operation
  • Thermostat staging
  • Air filter and airflow condition