S1-6HK16501306 York 13kw Elec Heater Kit with Breakers

S1-6HK16501306 York 13kw Elec Heater Kit with Breakers

  • $ 458.16
    Unit price per 
  • Save $ 31.62
Shipping calculated at checkout.


S1-6HK16501306 York 13kw Elec Heater Kit with Breakers

The York S1-6HK16501306 Electric Heat Kit is a 13 kW OEM electric heater assembly with integrated circuit breakers designed for compatible York, Coleman, and Luxaire air handlers. This factory-authorized heat strip kit provides dependable auxiliary and emergency heat while offering built-in overcurrent protection for safe, efficient HVAC system operation.


Cross-Reference

  • York S1-6HK16501306
  • S1-6HK16501306
  • 6HK16501306
  • HK16501306

Direct OEM

York S1-6HK16501306


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Johnson Controls

Application

Used in compatible air handlers and heat pump systems to:

  • Provide 13 kW electric heating capacity
  • Supply auxiliary heat during extreme weather conditions
  • Deliver emergency heat operation
  • Support residential and light commercial HVAC applications
  • Provide factory-approved supplemental heating

Related Components

  • Electric Heat Strip
  • Circuit Breaker Assembly
  • Heat Sequencer
  • High-Limit Switch
  • Air Handler Control Board
  • Transformer
  • Contactor
  • Thermostat
  • Blower Assembly

Technician Notes

The S1-6HK16501306 is a factory-engineered electric heater package equipped with integrated circuit breakers for electrical protection. Always verify voltage requirements and air handler compatibility before installation. Proper airflow across the heating elements is critical to prevent nuisance limit trips and maintain peak heating performance.


Common Symptoms of Failure

  • No auxiliary heat
  • No emergency heat operation
  • Circuit breakers tripping repeatedly
  • Open or failed heating elements
  • High-limit switch activation
  • Reduced heating output
  • Heater fails to energize
  • Burned electrical connections
  • Uneven supply air temperatures
  • Intermittent heat operation

Installation Tips

  1. Disconnect all electrical power before servicing.
  2. Verify heat kit compatibility with the air handler model.
  3. Confirm correct supply voltage and circuit sizing.
  4. Inspect all wiring and breaker connections.
  5. Check heating element resistance before startup.
  6. Verify sequencer and high-limit switch operation.
  7. Measure operating amperage after installation.
  8. Test auxiliary and emergency heat functions.
  9. Confirm proper airflow across the heater assembly.

Recommended Inspection Items

  • Heating elements
  • Integrated circuit breakers
  • Heat sequencers
  • High-limit switches
  • Electrical terminals
  • Supply voltage
  • Control board operation
  • Thermostat staging
  • Blower motor performance
  • Air filter and duct airflow