{"product_id":"s1-6hk16501006-york-10kw-elec-heat-kit","title":"S1-6HK16501006 York 10kw ELEC HEAT KIT","description":"\u003ch1\u003eS1-6HK16501006 York 10kw ELEC HEAT KIT\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eYork S1-6HK16501006 Electric Heat Kit\u003c\/strong\u003e is a \u003cstrong\u003e10 kW OEM electric heater assembly\u003c\/strong\u003e engineered for compatible York, Coleman, and Luxaire air handlers. Designed to provide supplemental, auxiliary, or emergency heat, this factory-authorized heat strip kit delivers reliable heating performance while maintaining proper equipment compatibility and airflow requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYork S1-6HK16501006\u003c\/li\u003e\n\u003cli\u003eS1-6HK16501006\u003c\/li\u003e\n\u003cli\u003e6HK16501006\u003c\/li\u003e\n\u003cli\u003eHK16501006\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eYork S1-6HK16501006\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eJohnson Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eUsed in compatible air handlers and heat pump systems to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvide 10 kW electric heat\u003c\/li\u003e\n\u003cli\u003eSupply auxiliary heat during high demand\u003c\/li\u003e\n\u003cli\u003eDeliver emergency heat operation\u003c\/li\u003e\n\u003cli\u003eEnhance comfort in low outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eSupport residential HVAC heating applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectric Heat Strip\u003c\/li\u003e\n\u003cli\u003eHeat Sequencer\u003c\/li\u003e\n\u003cli\u003eHigh-Limit Switch\u003c\/li\u003e\n\u003cli\u003eAir Handler Control Board\u003c\/li\u003e\n\u003cli\u003eTransformer\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Kit\u003c\/li\u003e\n\u003cli\u003eContactor\u003c\/li\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cp\u003eThe S1-6HK16501006 is a factory-designed 10 kW heater package intended for approved York-family air handlers. Always verify air handler model compatibility before installation. Inspect heating elements, safety limits, and wiring connections during service. Proper airflow is critical to prevent nuisance high-limit trips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo auxiliary heat\u003c\/li\u003e\n\u003cli\u003eNo emergency heat operation\u003c\/li\u003e\n\u003cli\u003eTripped circuit breaker\u003c\/li\u003e\n\u003cli\u003eOpen heating element\u003c\/li\u003e\n\u003cli\u003eHigh-limit switch trips\u003c\/li\u003e\n\u003cli\u003eReduced heating output\u003c\/li\u003e\n\u003cli\u003eUneven supply air temperatures\u003c\/li\u003e\n\u003cli\u003eBurned wiring or terminal connections\u003c\/li\u003e\n\u003cli\u003eSequencer failure preventing heater energization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify equipment compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm supply voltage matches heater specifications.\u003c\/li\u003e\n\u003cli\u003eInspect wiring and terminals for damage.\u003c\/li\u003e\n\u003cli\u003eCheck heating element resistance before startup.\u003c\/li\u003e\n\u003cli\u003eVerify all limit controls are operational.\u003c\/li\u003e\n\u003cli\u003eMeasure amperage draw after installation.\u003c\/li\u003e\n\u003cli\u003eTest auxiliary and emergency heat functions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeating elements\u003c\/li\u003e\n\u003cli\u003eHigh-limit switches\u003c\/li\u003e\n\u003cli\u003eSequencers\u003c\/li\u003e\n\u003cli\u003eElectrical terminals\u003c\/li\u003e\n\u003cli\u003eCircuit breakers\u003c\/li\u003e\n\u003cli\u003eAir handler blower performance\u003c\/li\u003e\n\u003cli\u003eControl board operation\u003c\/li\u003e\n\u003cli\u003eTransformer output\u003c\/li\u003e\n\u003cli\u003eThermostat staging\u003c\/li\u003e\n\u003cli\u003eAir filter and airflow conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45882986233922,"sku":"S1-6HK16501006","price":285.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-02094929.png?v=1793638228","url":"https:\/\/hvacpartstoremarket.com\/products\/s1-6hk16501006-york-10kw-elec-heat-kit","provider":"HVACpartstore","version":"1.0","type":"link"}