{"product_id":"s1-6hk16500506-york-5kw-heat-kit-w-breakers","title":"S1-6HK16500506 York 5KW Heat Kit W\/Breakers","description":"\u003ch1\u003eS1-6HK16500506 York 5KW Heat Kit W\/Breakers\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eYork S1-6HK16500506 Electric Heat Kit\u003c\/strong\u003e is a \u003cstrong\u003e5 kW OEM heat strip assembly with integrated circuit breakers\u003c\/strong\u003e, designed for compatible York, Coleman, and Luxaire air handlers. This factory-authorized heater kit provides supplemental, auxiliary, and emergency heat while offering built-in overcurrent protection for safe and reliable operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYork S1-6HK16500506\u003c\/li\u003e\n\u003cli\u003eS1-6HK16500506\u003c\/li\u003e\n\u003cli\u003e6HK16500506\u003c\/li\u003e\n\u003cli\u003eHK16500506\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eYork S1-6HK16500506\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eJohnson Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eUsed in compatible HVAC air handlers and heat pump systems to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvide 5 kW electric heating capacity\u003c\/li\u003e\n\u003cli\u003eSupply auxiliary heat during peak demand\u003c\/li\u003e\n\u003cli\u003eDeliver emergency heat operation\u003c\/li\u003e\n\u003cli\u003eEnhance cold-weather heating performance\u003c\/li\u003e\n\u003cli\u003eProtect heater circuits with factory-installed breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectric Heat Strip\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Kit\u003c\/li\u003e\n\u003cli\u003eHeat Sequencer\u003c\/li\u003e\n\u003cli\u003eHigh-Limit Switch\u003c\/li\u003e\n\u003cli\u003eAir Handler Control Board\u003c\/li\u003e\n\u003cli\u003eTransformer\u003c\/li\u003e\n\u003cli\u003eContactor\u003c\/li\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cp\u003eThe S1-6HK16500506 is a factory-engineered 5 kW heater package that includes integrated circuit breakers for added electrical protection. Verify equipment compatibility before installation and inspect heating elements, breaker operation, sequencers, and limit controls during service. Proper airflow is necessary to prevent overheating and nuisance limit trips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo auxiliary heat\u003c\/li\u003e\n\u003cli\u003eNo emergency heat operation\u003c\/li\u003e\n\u003cli\u003eTripped circuit breakers\u003c\/li\u003e\n\u003cli\u003eOpen heating element\u003c\/li\u003e\n\u003cli\u003eHigh-limit switch activation\u003c\/li\u003e\n\u003cli\u003eReduced heat output\u003c\/li\u003e\n\u003cli\u003eHeater not energizing\u003c\/li\u003e\n\u003cli\u003eBurned wire terminals\u003c\/li\u003e\n\u003cli\u003eIntermittent heating performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify heater kit compatibility with the air handler model.\u003c\/li\u003e\n\u003cli\u003eConfirm supply voltage matches heater specifications.\u003c\/li\u003e\n\u003cli\u003eInspect breakers for shipping or installation damage.\u003c\/li\u003e\n\u003cli\u003eCheck heating element resistance before startup.\u003c\/li\u003e\n\u003cli\u003eTighten all electrical connections.\u003c\/li\u003e\n\u003cli\u003eVerify proper sequencer and limit switch operation.\u003c\/li\u003e\n\u003cli\u003eMeasure operating amperage after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeating elements\u003c\/li\u003e\n\u003cli\u003eIntegrated circuit breakers\u003c\/li\u003e\n\u003cli\u003eHigh-limit switches\u003c\/li\u003e\n\u003cli\u003eHeat sequencers\u003c\/li\u003e\n\u003cli\u003eElectrical terminals\u003c\/li\u003e\n\u003cli\u003ePower wiring connections\u003c\/li\u003e\n\u003cli\u003eControl board operation\u003c\/li\u003e\n\u003cli\u003eThermostat staging\u003c\/li\u003e\n\u003cli\u003eBlower performance\u003c\/li\u003e\n\u003cli\u003eAir filter and airflow condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45883108491330,"sku":"S1-6HK16500506","price":255.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-02102107.png?v=1793640078","url":"https:\/\/hvacpartstoremarket.com\/products\/s1-6hk16500506-york-5kw-heat-kit-w-breakers","provider":"HVACpartstore","version":"1.0","type":"link"}