S1-431-01972-100 Furnace Control Board Kit
S1-431-01972-100 Furnace Control Board Kit
The S1-431-01972-100 Furnace Control Board Kit is a genuine OEM replacement integrated furnace control designed for select York, Coleman, Luxaire, and Fraser-Johnston heating systems. This control board manages critical furnace operations including ignition sequencing, blower motor control, safety monitoring, and thermostat communication. Engineered to original equipment specifications, the S1-431-01972-100 provides reliable system performance and is an ideal solution for replacing failed, damaged, or obsolete control boards.
This kit serves as the approved replacement for older control board 031-01267-001, restoring proper furnace operation and diagnostic functionality.
Cross-Reference
- S1-431-01972-100
- 431-01972-100
- S143101972100
- 031-01267-001
- Furnace Control Board Kit
- Integrated Furnace Control
Direct OEM
Yes – Genuine Source 1 / York OEM replacement control board kit.
Compatible Brands
- York
- Coleman
- Luxaire
- Fraser-Johnston
- Evcon
Always verify compatibility using the furnace model and serial number.
Application
- Gas furnaces
- Residential heating systems
- Integrated ignition control systems
- Furnace blower control applications
- OEM replacement control board upgrades
- Replacement for obsolete control boards
Related Components
- Flame sensors
- Hot surface ignitors
- Pressure switches
- Limit switches
- Rollout switches
- Blower motors
- Transformers
- Thermostats
Technician Notes
- Genuine OEM replacement control board kit.
- Replaces obsolete board 031-01267-001.
- Controls furnace ignition, blower operation, and safety circuits.
- Verify all wiring locations before removing the original board.
- Inspect wire terminals and harnesses for heat damage.
- Transfer wiring one terminal at a time during installation.
- Review furnace fault codes after startup.
Common Symptoms of Failure
- No heat operation
- Blower motor not functioning
- Ignition sequence failure
- Intermittent furnace operation
- Diagnostic fault codes
- Burned circuit board components
- Furnace lockout condition
- Loss of thermostat communication
Installation Tips
- Disconnect power before servicing.
- Photograph all wiring connections before removal.
- Verify replacement board part number.
- Inspect all connectors and terminals.
- Transfer wiring carefully to matching terminals.
- Secure the control board properly in the mounting location.
- Restore power and check LED diagnostic indicators.
- Verify complete heating cycle operation.
Recommended Inspection Items
- Flame sensor condition
- Ignitor operation
- Pressure switch tubing
- High-limit controls
- Rollout switches
- Transformer voltage
- Thermostat wiring
- Blower motor operation
- Wiring harness connections
Replaces old board 031-01267-001