colemanhvacparts.com, www.darindevries.com

S1-3400-3151 York 125-175F AUTO Limit Switch

  • $ 38.25
    Unit price per 
  • Save $ 3.64
Shipping calculated at checkout.


S1-3400-3151 York 125-175F AUTO Limit Switch

The York S1-3400-3151 Automatic Limit Switch is an OEM temperature safety control designed to protect furnaces and air handlers from overheating. Rated 125°F to 175°F with automatic reset operation, this limit switch monitors air temperature within the heating system and opens the control circuit when excessive temperatures occur, helping prevent equipment damage and ensuring safe HVAC operation.


Cross-Reference

  • York S1-3400-3151
  • S1-34003151
  • 3400-3151
  • 34003151

Direct OEM

York S1-3400-3151


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Fraser-Johnston
  • Johnson Controls

Application

Used in compatible HVAC equipment to:

  • Protect against excessive operating temperatures
  • Interrupt heating circuits during overheating conditions
  • Safeguard heat exchangers and internal components
  • Automatically restore operation after cooling
  • Maintain system safety and reliability

Related Components

  • High Limit Switch
  • Rollout Switch
  • Fan Limit Control
  • Furnace Control Board
  • Blower Motor
  • Transformer
  • Gas Valve
  • Flame Sensor

Technician Notes

The S1-3400-3151 is an automatic reset temperature limit switch with a 125°F to 175°F operating range. Repeated limit trips typically indicate an airflow restriction, dirty evaporator coil, plugged air filter, undersized ductwork, failing blower motor, or improper heating input. Correct the root cause of overheating before replacing the limit switch.


Common Symptoms of Failure

  • Furnace will not heat
  • Intermittent heating operation
  • Frequent system shutdowns
  • Open limit fault codes
  • Burner shuts down prematurely
  • Short cycling
  • No continuity through switch
  • Repeated lockout conditions

Installation Tips

  1. Disconnect power before servicing.
  2. Match temperature ratings to the original switch.
  3. Inspect mounting location for heat damage.
  4. Verify terminal connections are secure.
  5. Check airflow and filter condition before replacement.
  6. Test switch continuity as needed.
  7. Verify proper system operation after installation.
  8. Confirm temperature rise is within manufacturer specifications.

Recommended Inspection Items

  • Air filter condition
  • Blower motor operation
  • Evaporator coil cleanliness
  • Duct airflow
  • Heat exchanger condition
  • Control board diagnostics
  • Gas pressure settings
  • Wiring terminals
  • Venting system condition