colemanhvacparts.com, www.darindevries.com

S1-2702-321P York / Coleman 115V Vent Blower Assembly

  • $ 469.28
    Unit price per 
  • Save $ 43.60
Shipping calculated at checkout.


S1-2702-321P York / Coleman 115V Vent Blower Assembly

The S1-2702-321P Vent Blower Assembly is a genuine OEM replacement draft inducer blower designed for select York, Coleman, Luxaire, and Fraser-Johnston gas furnaces. This assembly features a 115-volt, 0.02 HP shaded pole motor operating at approximately 3300 RPM, providing the necessary draft and combustion airflow required for safe furnace ignition and operation. Engineered to OEM specifications, this vent blower helps maintain proper venting performance, pressure switch operation, and combustion efficiency.

Built with a 3.3-inch diameter motor, sleeve bearings, thermal overload protection, and Class B insulation, the S1-2702-321P delivers reliable performance in residential heating applications.


Cross-Reference

  • S1-2702-321P
  • 2702-321P
  • 2702-321
  • 2702-321P/A
  • 2702-320
  • 2702-320P
  • 2702-320P/A
  • 2702-3201A
  • 026-34024-000
  • 026-34720-000
  • 7021-8935
  • 7021-10882
  • JA1P092
  • Packard A156
  • Fasco 7021-8935
  • Fasco 7021-10882

Direct OEM

Yes – Genuine Source 1 / York / Coleman OEM replacement draft inducer blower assembly.


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Fraser-Johnston
  • Evcon

Always verify compatibility by model number and original inducer assembly part number.


Application

  • Gas furnaces
  • Draft inducer systems
  • Vent blower assemblies
  • Combustion air movement
  • Furnace venting systems
  • OEM replacement applications

Related Components

  • Pressure switches
  • Ignitors
  • Flame sensors
  • Inducer gaskets
  • Vent pipe assemblies
  • Control boards
  • Limit switches
  • Gas valves

Technician Notes

  • OEM Direct Replacement Draft Inducer Blower
  • 115 Volt operation
  • 0.02 HP motor
  • 3300 RPM
  • Single speed
  • 3.3" motor diameter
  • Shaded pole motor design
  • Thermally protected
  • Open air-over construction
  • Sleeve bearing design
  • Class B insulation
  • 40°C ambient rating
  • 5" leads with socket terminals

Motor Specifications

  • Voltage: 115V
  • Amperage: 1.10A
  • Frequency: 60 Hz
  • Phase: Single Phase
  • Speed: 1
  • RPM: 3000-3300
  • Bearings: Sleeve
  • Frame: 3.3
  • Enclosure: Open

Common Symptoms of Failure

  • Pressure switch faults
  • Furnace will not ignite
  • Inducer motor not running
  • Excessive inducer noise
  • Bearing squeal or grinding
  • Intermittent ignition problems
  • Draft proving failures
  • Combustion airflow errors

Installation Tips

  1. Disconnect electrical power before servicing.
  2. Verify replacement part number compatibility.
  3. Inspect venting and pressure switch tubing.
  4. Replace damaged inducer gaskets during installation.
  5. Check blower wheel for debris accumulation.
  6. Confirm proper rotation and airflow.
  7. Verify pressure switch operation after startup.
  8. Perform a complete heating cycle test.

Recommended Inspection Items

  • Pressure switch tubing
  • Vent pipe condition
  • Inducer mounting gasket
  • Ignitor operation
  • Flame sensor condition
  • Control board diagnostics
  • Heat exchanger condition
  • Combustion air intake
  • Furnace vent termination