S1-029-20422-065 York Nat Gas Pilot Orifice #48 (.035)
S1-029-20422-065 York Nat Gas Pilot Orifice #48 (.035)
The S1-029-20422-065 York Natural Gas Pilot Orifice #48 (.035) is a genuine OEM replacement pilot orifice designed to provide precise natural gas flow for dependable pilot ignition and stable flame performance. Featuring a #48 drill size with a .035-inch orifice opening, this component helps maintain proper pilot flame characteristics, reliable thermocouple heating, and consistent burner operation. Manufactured to York OEM specifications, this pilot orifice is ideal for restoring proper ignition performance in compatible York and Source 1 heating equipment.
Cross-Reference
- S1-029-20422-065
- 029-20422-065
- York S1-029-20422-065
- Source 1 S1-029-20422-065
- #48 Pilot Orifice
- .035 Natural Gas Pilot Orifice
Direct OEM
Yes
Genuine York Source 1 OEM replacement part.
Compatible Brands
- York
- Source 1
- Johnson Controls
- Luxaire
- Coleman
- Fraser-Johnston
Application
Designed for Natural Gas (NG) pilot burner applications requiring a #48 (.035") pilot orifice.
Commonly used in:
- Gas Furnaces
- Unit Heaters
- Commercial Heating Equipment
- Standing Pilot Systems
- Gas-Fired Heating Appliances
Always verify model compatibility and orifice size requirements before ordering.
Related Components
- Pilot Assemblies
- Thermocouples
- Thermopiles
- Pilot Tubing
- Gas Valves
- Burner Assemblies
- Ignition Controls
- Flame Safety Components
Technician Notes
- Genuine York Source 1 OEM component.
- Precision-drilled #48 (.035") opening for accurate natural gas flow.
- A plugged or partially restricted orifice can cause poor pilot flame performance.
- Inspect pilot tubing and burner components for contamination when replacing the orifice.
- Confirm proper pilot flame impingement on the thermocouple after installation.
- Verify gas pressure settings according to manufacturer specifications.
Common Symptoms of Failure
- Pilot will not light
- Weak pilot flame
- Pilot outage conditions
- Delayed burner ignition
- Thermocouple not heating properly
- Intermittent heating operation
- Burner ignition failures
- Restricted pilot gas flow
Installation Tips
- Disconnect electrical power and shut off the gas supply.
- Verify the appliance is configured for natural gas.
- Carefully remove the existing pilot orifice.
- Inspect pilot tubing and pilot burner for dirt or debris.
- Install the new S1-029-20422-065 orifice securely.
- Leak-test all gas connections after service.
- Verify proper pilot flame size and stability.
- Follow OEM service procedures and local codes.
Recommended Inspection Items
- Thermocouple condition
- Pilot burner cleanliness
- Pilot tubing condition
- Gas valve operation
- Gas supply pressure
- Burner ignition sequence
- Venting system condition
- Flame quality and stability
- Combustion air intake