{"product_id":"s1-029-20422-063-york-63-pilot-orifice-037","title":"S1-029-20422-063 York #63 Pilot Orifice (.037)","description":"\u003ch1\u003eS1-029-20422-063 York #63 Pilot Orifice (.037)\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eS1-029-20422-063 York #63 Pilot Orifice (.037)\u003c\/strong\u003e is a genuine OEM replacement pilot orifice designed to deliver precise gas flow for reliable pilot ignition and consistent flame performance. Featuring a \u003cstrong\u003e#63 drill size with a .037-inch orifice opening\u003c\/strong\u003e, this component helps maintain proper pilot flame characteristics, dependable thermocouple heating, and safe operation of compatible gas-fired heating equipment. Manufactured to York Source 1 specifications, this pilot orifice is ideal for restoring proper ignition performance and pilot burner operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eS1-029-20422-063\u003c\/li\u003e\n\u003cli\u003e029-20422-063\u003c\/li\u003e\n\u003cli\u003eYork S1-029-20422-063\u003c\/li\u003e\n\u003cli\u003eSource 1 S1-029-20422-063\u003c\/li\u003e\n\u003cli\u003e#63 Pilot Orifice\u003c\/li\u003e\n\u003cli\u003e.037 Pilot Orifice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenuine York Source 1 OEM replacement part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eSource 1\u003c\/li\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eJohnson Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eDesigned for gas pilot burner systems requiring a \u003cstrong\u003e#63 (.037\") pilot orifice\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas Furnaces\u003c\/li\u003e\n\u003cli\u003eUnit Heaters\u003c\/li\u003e\n\u003cli\u003eResidential Heating Equipment\u003c\/li\u003e\n\u003cli\u003eCommercial Heating Equipment\u003c\/li\u003e\n\u003cli\u003eStanding Pilot Ignition Systems\u003c\/li\u003e\n\u003cli\u003eGas-Fired Appliances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify equipment model number and parts list compatibility before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePilot Burner Assemblies\u003c\/li\u003e\n\u003cli\u003eThermocouples\u003c\/li\u003e\n\u003cli\u003eThermopiles\u003c\/li\u003e\n\u003cli\u003ePilot Tubing\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eIgnition Controls\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine York Source 1 OEM replacement component.\u003c\/li\u003e\n\u003cli\u003ePrecision-machined \u003cstrong\u003e#63 (.037\") orifice opening\u003c\/strong\u003e for accurate pilot gas delivery.\u003c\/li\u003e\n\u003cli\u003eProper pilot flame size is critical for thermocouple operation and ignition reliability.\u003c\/li\u003e\n\u003cli\u003eContamination or blockage inside the orifice can cause weak flame conditions.\u003c\/li\u003e\n\u003cli\u003eInspect pilot tubing and burner assemblies during replacement.\u003c\/li\u003e\n\u003cli\u003eVerify gas pressure settings and pilot flame quality after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePilot will not light\u003c\/li\u003e\n\u003cli\u003eWeak pilot flame\u003c\/li\u003e\n\u003cli\u003ePilot will not remain lit\u003c\/li\u003e\n\u003cli\u003eDelayed burner ignition\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003ePoor thermocouple heating\u003c\/li\u003e\n\u003cli\u003eRestricted pilot gas flow\u003c\/li\u003e\n\u003cli\u003eNuisance shutdowns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eTurn off electrical power and shut off the gas supply.\u003c\/li\u003e\n\u003cli\u003eConfirm equipment compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eRemove the existing pilot orifice carefully.\u003c\/li\u003e\n\u003cli\u003eInspect the pilot assembly for dirt, rust, or debris.\u003c\/li\u003e\n\u003cli\u003eInstall the new S1-029-20422-063 orifice securely.\u003c\/li\u003e\n\u003cli\u003eLeak-test all gas connections after servicing.\u003c\/li\u003e\n\u003cli\u003eVerify proper pilot flame size and stability.\u003c\/li\u003e\n\u003cli\u003eFollow OEM service procedures and local codes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple condition\u003c\/li\u003e\n\u003cli\u003ePilot burner cleanliness\u003c\/li\u003e\n\u003cli\u003ePilot tubing condition\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eGas supply pressure\u003c\/li\u003e\n\u003cli\u003eBurner ignition sequence\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003cli\u003eFlame stability\u003c\/li\u003e\n\u003cli\u003eCombustion air openings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45879279419458,"sku":"S1-02920422063","price":30.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-01215533.png?v=1793595344","url":"https:\/\/hvacpartstoremarket.com\/products\/s1-029-20422-063-york-63-pilot-orifice-037","provider":"HVACpartstore","version":"1.0","type":"link"}