S1-029-20422-063 York #63 Pilot Orifice (.037)
S1-029-20422-063 York #63 Pilot Orifice (.037)
The S1-029-20422-063 York #63 Pilot Orifice (.037) is a genuine OEM replacement pilot orifice designed to deliver precise gas flow for reliable pilot ignition and consistent flame performance. Featuring a #63 drill size with a .037-inch orifice opening, this component helps maintain proper pilot flame characteristics, dependable thermocouple heating, and safe operation of compatible gas-fired heating equipment. Manufactured to York Source 1 specifications, this pilot orifice is ideal for restoring proper ignition performance and pilot burner operation.
Cross-Reference
- S1-029-20422-063
- 029-20422-063
- York S1-029-20422-063
- Source 1 S1-029-20422-063
- #63 Pilot Orifice
- .037 Pilot Orifice
Direct OEM
Yes
Genuine York Source 1 OEM replacement part.
Compatible Brands
- York
- Source 1
- Coleman
- Luxaire
- Fraser-Johnston
- Johnson Controls
Application
Designed for gas pilot burner systems requiring a #63 (.037") pilot orifice.
Commonly used in:
- Gas Furnaces
- Unit Heaters
- Residential Heating Equipment
- Commercial Heating Equipment
- Standing Pilot Ignition Systems
- Gas-Fired Appliances
Always verify equipment model number and parts list compatibility before ordering.
Related Components
- Pilot Burner Assemblies
- Thermocouples
- Thermopiles
- Pilot Tubing
- Gas Valves
- Ignition Controls
- Flame Sensors
- Burner Assemblies
Technician Notes
- Genuine York Source 1 OEM replacement component.
- Precision-machined #63 (.037") orifice opening for accurate pilot gas delivery.
- Proper pilot flame size is critical for thermocouple operation and ignition reliability.
- Contamination or blockage inside the orifice can cause weak flame conditions.
- Inspect pilot tubing and burner assemblies during replacement.
- Verify gas pressure settings and pilot flame quality after installation.
Common Symptoms of Failure
- Pilot will not light
- Weak pilot flame
- Pilot will not remain lit
- Delayed burner ignition
- Intermittent heating operation
- Poor thermocouple heating
- Restricted pilot gas flow
- Nuisance shutdowns
Installation Tips
- Turn off electrical power and shut off the gas supply.
- Confirm equipment compatibility before installation.
- Remove the existing pilot orifice carefully.
- Inspect the pilot assembly for dirt, rust, or debris.
- Install the new S1-029-20422-063 orifice securely.
- Leak-test all gas connections after servicing.
- Verify proper pilot flame size and stability.
- Follow OEM service procedures and local codes.
Recommended Inspection Items
- Thermocouple condition
- Pilot burner cleanliness
- Pilot tubing condition
- Gas valve operation
- Gas supply pressure
- Burner ignition sequence
- Venting system condition
- Flame stability
- Combustion air openings