S1-029-20422-060 York Gas PILOT #60 (.040) Orifice
S1-029-20422-060 York Gas PILOT #60 (.040) Orifice
The S1-029-20422-060 York Gas Pilot #60 (.040) Orifice is a genuine OEM replacement pilot orifice designed to provide precise gas flow for dependable pilot ignition and consistent flame performance. Featuring a #60 drill size with a .040-inch opening, this pilot orifice helps maintain proper pilot flame characteristics, reliable thermocouple heating, and efficient burner operation. Manufactured to York Source 1 specifications, the S1-029-20422-060 is ideal for restoring proper pilot burner performance in compatible gas-fired heating equipment.
Cross-Reference
- S1-029-20422-060
- 029-20422-060
- York S1-029-20422-060
- Source 1 S1-029-20422-060
- #60 Pilot Orifice
- .040 Gas Pilot Orifice
Direct OEM
Yes
Genuine York Source 1 OEM replacement part.
Compatible Brands
- York
- Source 1
- Coleman
- Luxaire
- Fraser-Johnston
- Johnson Controls
Application
Designed for gas pilot burner systems requiring a #60 (.040") pilot orifice.
Commonly used in:
- Gas Furnaces
- Unit Heaters
- Residential Heating Systems
- Commercial Heating Equipment
- Standing Pilot Systems
- Gas-Fired Appliances
Always verify model and serial number compatibility before ordering.
Related Components
- Pilot Burner Assemblies
- Thermocouples
- Thermopiles
- Pilot Tubing
- Gas Valves
- Ignition Controls
- Flame Sensors
- Burner Assemblies
Technician Notes
- Genuine York Source 1 OEM replacement component.
- Precision-drilled #60 (.040") orifice opening for accurate pilot gas delivery.
- Proper pilot flame size is critical for ignition reliability and thermocouple performance.
- Inspect pilot tubing and burner ports for debris or contamination during service.
- Verify gas pressure and pilot flame characteristics after installation.
- Replace damaged or clogged orifices to restore proper system operation.
Common Symptoms of Failure
- Pilot will not light
- Weak pilot flame
- Pilot will not stay lit
- Delayed burner ignition
- Poor thermocouple heating
- Intermittent heating operation
- Restricted pilot gas flow
- Nuisance shutdowns
Installation Tips
- Shut off electrical power and gas supply before servicing.
- Verify compatibility with the equipment model number.
- Remove the existing pilot orifice carefully.
- Inspect the pilot assembly and tubing for contamination.
- Install the new S1-029-20422-060 orifice securely.
- Leak-test all gas connections after installation.
- Verify proper pilot flame appearance and stability.
- Follow manufacturer service instructions and local codes.
Recommended Inspection Items
- Thermocouple condition
- Pilot burner cleanliness
- Pilot tubing condition
- Gas valve operation
- Gas supply pressure
- Burner ignition sequence
- Venting system condition
- Flame quality and stability
- Combustion air openings