S1-029-20422-056 York #56 Pilot Orifice (.0465)
S1-029-20422-056 York #56 Pilot Orifice (.0465)
The S1-029-20422-056 York #56 Pilot Orifice (.0465) is a genuine OEM replacement pilot orifice designed to provide accurate gas flow for reliable pilot ignition and consistent flame performance. Featuring a #56 drill size with a .0465-inch orifice opening, this precision-machined component helps maintain proper pilot flame characteristics, dependable thermocouple heating, and efficient burner operation. Manufactured to York Source 1 specifications, the S1-029-20422-056 is an ideal replacement for worn, damaged, or restricted pilot orifices in compatible gas-fired heating equipment.
Cross-Reference
- S1-029-20422-056
- 029-20422-056
- York S1-029-20422-056
- Source 1 S1-029-20422-056
- #56 Pilot Orifice
- .0465 Pilot Orifice
Direct OEM
Yes
Genuine York Source 1 OEM replacement part.
Compatible Brands
- York
- Coleman
- Luxaire
- Fraser-Johnston
- Source 1
- Johnson Controls
Application
Designed for gas pilot burner systems requiring a #56 (.0465") pilot orifice.
Commonly used in:
- Gas Furnaces
- Unit Heaters
- Residential Heating Equipment
- Commercial Heating Equipment
- Standing Pilot Ignition Systems
- Gas-Fired Appliances
Always verify model number and parts breakdown compatibility before ordering.
Related Components
- Pilot Burner Assemblies
- Thermocouples
- Thermopiles
- Pilot Tubing
- Gas Valves
- Ignition Controls
- Flame Sensors
- Burner Assemblies
Technician Notes
- Genuine York Source 1 OEM replacement component.
- Precision-machined #56 (.0465") opening for proper pilot gas flow.
- Pilot flame quality directly impacts thermocouple performance and ignition reliability.
- Inspect pilot tubing, burner ports, and adjacent components for contamination during replacement.
- Verify correct fuel type and pilot flame characteristics after installation.
- Replace damaged or obstructed orifices to restore proper ignition performance.
Common Symptoms of Failure
- Pilot will not light
- Weak pilot flame
- Pilot will not stay lit
- Delayed ignition
- Poor thermocouple heating
- Intermittent burner operation
- Restricted pilot gas flow
- Nuisance shutdowns
Installation Tips
- Turn off electrical power and shut off the gas supply.
- Verify replacement part number compatibility.
- Carefully remove the existing pilot orifice.
- Inspect pilot tubing and burner components for debris.
- Install the new S1-029-20422-056 orifice securely.
- Leak-test all gas connections after installation.
- Verify proper pilot flame size and stability.
- Follow York OEM specifications and local codes.
Recommended Inspection Items
- Thermocouple condition
- Pilot burner cleanliness
- Pilot tubing condition
- Gas valve operation
- Gas supply pressure
- Burner ignition sequence
- Venting system condition
- Flame stability
- Combustion air openings