The S1-026-34028-001 L155F-30 Limit Switch is a genuine OEM Coleman and York furnace safety control designed to protect the heat exchanger from overheating. Rated to open at 155°F with a 30°F differential, this automatic reset limit switch interrupts burner operation when excessive temperatures are detected and restores operation once temperatures return to a safe range. Featuring a 3-inch insertion length and a mounting plate measuring 1-7/8" x 2-3/4", this switch is commonly used in Coleman PTUHB furnaces and all G8C series units.
Cross‑Reference
- S1-026-34028-001
- 026-34028-001
- S1-02634028001
- 026-34726-002
- 2702-315P/A
- 2702-3151/A
- 2702-315P
- 2702-315
- L155F-30
- 1NT17L
- 36T01B3
Direct OEM
Yes, Genuine OEM Coleman / York Limit Switch.
Compatible Brands
- Coleman
- York
- Luxaire
- Fraser-Johnston
Verify model and serial number compatibility before ordering.
Application
- Coleman PTUHB Furnaces
- Coleman G8C Series Furnaces
- Residential Gas Furnaces
- Mobile Home Furnaces
- Furnace Over-Temperature Protection Circuits
Specifications
- Temperature Rating: L155°F
- Differential: 30°F
- Insertion Length: 3"
- Mounting Plate Size: 1-7/8" x 2-3/4"
- Auto Reset Design
Related Components
- Flame Sensors
- Pressure Switches
- Blower Motors
- Run Capacitors
- Control Boards
- Rollout Switches
- Induced Draft Motors
- Fan Limit Controls
- Air Filters
- Heat Exchanger Components
Technician Notes
- A failed limit switch is often a symptom rather than the root cause.
- Always inspect airflow-related components before replacing the switch.
- Verify blower performance and temperature rise across the heat exchanger.
- Check for dirty evaporator coils, blocked vents, or restricted filters.
- Replace any limit switch showing signs of overheating, pitted terminals, or intermittent operation.
Common Symptoms of Failure
- Furnace will not fire
- Burners shut off prematurely
- Furnace short cycles
- High-limit fault codes
- Intermittent heating
- Blower runs continuously
- Lockout conditions
- Excessive cabinet temperatures
Installation Tips
- Disconnect electrical power to the furnace.
- Verify the replacement switch matches the original temperature rating.
- Remove wiring from the existing switch.
- Remove mounting screws and old limit switch.
- Install replacement switch securely.
- Reconnect wiring terminals.
- Restore power and test furnace operation.
- Verify proper temperature rise and airflow.
Recommended Inspection Items
- Air Filter Condition
- Blower Wheel Cleanliness
- Blower Motor Operation
- Evaporator Coil
- Supply and Return Airflow
- Heat Exchanger
- Vent System
- Control Board Diagnostics
- Temperature Rise Across Furnace
- Burner Operation
Replaces: 026-34028-001, S1-026-34028-001
L155-30F Coleman 3" limit switch. Back plate measures 1-7/8" x 2-3/4". Replaces 026-34726-002, 2702-315P/A, 2702-3151/A, 2702-315P, 2702-315 & S1-02634028001,. Sizes are 1NT17L or 36T01B3. For use with PTUHB and all G8C units.