S1-025-32607-000 York - Source 1 Limit Switch L185F-30 Coleman 3"
S1-025-32607-000 York - Source 1 Limit Switch L185F-30 Coleman 3"
he S1-025-32607-000 Limit Switch is a genuine OEM Source 1 replacement safety control designed for use in select York, Coleman, Luxaire, Fraser-Johnston, and Evcon furnaces. Rated L185-30F, this automatic reset limit switch opens the control circuit when temperatures reach approximately 185°F and automatically resets after temperatures decrease by 30°F, helping protect the furnace from overheating conditions.
Featuring a 3-inch sensing probe, the S1-025-32607-000 is engineered to monitor heat exchanger temperatures and prevent excessive operating temperatures that can damage furnace components. Manufactured to OEM specifications, this limit switch helps maintain safe, reliable furnace operation and proper temperature control.
Cross-Reference
- S1-025-32607-000
- S102532607000
- York S1-025-32607-000
- Coleman Limit Switch
- L185-30F Limit Switch
- 3" Furnace Limit Switch
- High Limit Switch
Direct OEM
Yes – Genuine Source 1 / York OEM replacement limit switch.
Compatible Brands
- York
- Coleman
- Luxaire
- Fraser-Johnston
- Evcon
Always verify compatibility using the equipment model number and original limit switch specifications.
Specifications
| Specification | Value |
|---|---|
| Part Number | S1-025-32607-000 |
| Temperature Rating | L185-30F |
| Open Temperature | 185°F |
| Reset Temperature Differential | 30°F |
| Reset Type | Automatic |
| Probe Length | 3" |
| Application | Furnace High-Limit Safety Control |
Application
- Gas furnaces
- Residential heating systems
- Manufactured housing furnaces
- Over-temperature protection circuits
- Heat exchanger safety controls
- OEM furnace repairs
Related Components
- Rollout switches
- Pressure switches
- Furnace control boards
- Flame sensors
- Hot surface ignitors
- Blower motors
- Air filters
- Heat exchanger components
Technician Notes
- Genuine OEM Source 1 replacement limit switch.
- L185-30F temperature rating.
- Opens at 185°F and automatically resets after cooling.
- 3-inch sensing probe design.
- Protects heat exchanger and furnace components from overheating.
- Repeated limit trips typically indicate airflow restrictions, dirty filters, blower motor issues, duct restrictions, or venting problems.
- Always diagnose the cause of overheating before replacing the switch.
Common Symptoms of Failure
- Furnace shuts down during heating cycle
- Open limit switch fault codes
- Intermittent heating operation
- Blower runs continuously
- Furnace lockout conditions
- No heat complaints
- High temperature safety trips
- Overheating shutdowns
Installation Tips
- Disconnect electrical power before servicing.
- Verify temperature rating and probe length match the original switch.
- Inspect wiring terminals for signs of overheating.
- Install the sensing probe fully into the factory mounting location.
- Secure the switch using original hardware.
- Restore power and test furnace operation.
- Verify proper airflow and temperature rise.
- Confirm normal furnace cycling through a complete heating sequence.
Recommended Inspection Items
- Air filter condition
- Blower motor operation
- Heat exchanger condition
- Venting system
- Rollout switches
- Pressure switches
- Control board diagnostics
- Supply and return airflow
- Furnace temperature rise
L185F-30 Coleman 3" limit switch. Back plate measures 2-5/16" x 1/2". Also known as part number S1-02532607000, 36T01B3-44731 & 1NT23L-2815.
Used on the following units: DAYA-F048N135C, DAYH-F060N110C, DL-06N12ATAAA1A, DL-06N12AWAAA1A, DL-07N12ATAAA1A, DL-07N12AWAAA1A & DL-08N12ATAAA1A.