S1-024-40903-000 MTR BLW 1/3 950/4 CW 230v 1ph

The S1‑024‑40903‑000 is a genuine OEM 1/3 horsepower blower motor designed for Coleman, York, Luxaire, Fraser‑Johnston, and Guardian HVAC systems. Operating on 230 volts, this motor delivers 950 RPM and features a 4‑speed configuration, providing the airflow required for efficient heating, cooling, and air circulation.

If you're working on a Coleman EB-series electric furnace (EB10B, EB12B, EB15B, EB17B, EB20B, EB23B), S1-024-40903-000 is the current OEM replacement for S1-024-27651-000.

Engineered to Source 1 factory specifications, the S1‑024‑40903‑000 helps maintain proper furnace temperature rise, evaporator airflow, and overall HVAC system performance. Its clockwise (CW) rotation and OEM design ensure proper fit and compatibility with approved equipment.

This blower motor is ideal for replacing worn, noisy, overheating, or failed motors to restore reliable airflow and efficient system operation.


 Cross‑Reference 

Replaces: S1-024-27651-000

Direct OEM

  • S1‑024‑40903‑000
  • S1-024-27651-000
  • 024‑40903‑000
  • York Source 1 Blower Motor

Compatible Brands

  • Coleman
  • York
  • Luxaire
  • Fraser‑Johnston
  • Guardian

Specifications

  • Horsepower: 1/3 HP
  • Voltage: 230 VAC
  • Speed: 950 RPM
  • Speed Taps: 4 Speed
  • Rotation: CW (Clockwise)
  • Phase: 1 Phase
  • Application: Furnace / Air Handler Blower Motor
  • OEM Replacement: Yes

Applications

  • Residential Furnaces
  • Air Handlers
  • Package Units
  • Indoor Blower Assemblies
  • HVAC Air Circulation Systems

Related Components

  • Run Capacitors
  • Blower Wheels
  • Fan Relays
  • Control Boards
  • Motor Mount Brackets
  • Limit Switches

 Technician Notes

Common Symptoms of Failure

  • Blower motor will not start
  • Weak airflow
  • Excessive motor noise
  • Bearing squeal
  • Motor overheating
  • Intermittent blower operation
  • High amp draw

Installation Tips

  • Verify rotation direction before installation.
  • Match capacitor specifications exactly.
  • Inspect blower wheel for dirt buildup or imbalance.
  • Check all motor mounts and brackets.
  • Verify motor amperage after installation.
  • Replace damaged wiring terminals if heat discoloration is present.

Recommended Inspection Items

  • Run capacitor
  • Blower wheel
  • Control board
  • Fan relay
  • Air filter