S1-024-27632-001 York Pressure Switch.4"WC SPNO Close On Fall # Sw

  • $ 61.87
    Unit price per 
  • Save $ 4.33
Shipping calculated at checkout.


S1-024-27632-001 York Pressure Switch.4"WC SPNO Close On Fall #  Sw

The S1-024-27632-001 Pressure Switch is a genuine OEM York pressure switch designed for use in select York, Coleman, Luxaire, and Fraser-Johnston gas furnaces. Rated at 0.40" Water Column (WC), this SPNO (Single Pole Normally Open) pressure switch is designed to close on pressure fall, providing critical verification of inducer and venting system operation before allowing the ignition sequence to proceed.

As an essential furnace safety component, the pressure switch monitors combustion airflow and vent system performance. If proper draft conditions are not achieved, the switch prevents burner operation to help ensure safe and reliable furnace performance.


Cross-Reference

  • S1-024-27632-001
  • S102427632001
  • York S1-024-27632-001
  • Pressure Switch
  • .40" WC Pressure Switch
  • SPNO Close on Fall Pressure Switch

Direct OEM

Yes – Genuine Source 1 / York OEM replacement pressure switch.


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Fraser-Johnston
  • Evcon

Always verify compatibility using the equipment model number and original pressure switch rating.


Specifications

Specification Value
Part Number S1-024-27632-001
Pressure Rating 0.40" WC
Switch Type SPNO (Single Pole Normally Open)
Action Close on Fall
Application Furnace Draft Verification
OEM Source 1 / York

Application

  • Gas furnaces
  • Induced draft systems
  • Combustion airflow proving
  • Vent pressure monitoring
  • Furnace safety circuits
  • OEM replacement repairs

Related Components

  • Draft inducer motors
  • Vent blower assemblies
  • Pressure switch tubing
  • Furnace control boards
  • Flame sensors
  • Hot surface ignitors
  • Limit switches
  • Condensate drain assemblies

Technician Notes

  • Genuine OEM furnace safety control.
  • Monitors inducer-generated pressure conditions.
  • Required for safe ignition sequence operation.
  • Switch closes when proper pressure conditions are achieved.
  • Always inspect pressure tubing before replacing the switch.
  • Verify venting, condensate drains, and inducer operation when troubleshooting pressure switch faults.
  • Match the exact pressure rating when replacing.

Common Symptoms of Failure

  • Furnace will not ignite
  • Pressure switch fault codes
  • Inducer motor runs but burners do not light
  • Intermittent heating operation
  • Ignition lockout conditions
  • Open pressure switch errors
  • Draft proving failures
  • Heating cycle interruptions

Installation Tips

  1. Disconnect electrical power before servicing.
  2. Verify the replacement pressure rating matches the original switch.
  3. Inspect pressure tubing for cracks, moisture, or blockages.
  4. Check draft inducer performance.
  5. Install the switch in the original mounting location.
  6. Reconnect tubing securely.
  7. Restore power and test furnace operation.
  8. Verify proper ignition sequence through multiple heating cycles.

Recommended Inspection Items

  • Draft inducer assembly
  • Pressure switch tubing
  • Vent piping
  • Condensate drain system
  • Furnace control board
  • Flame sensor
  • Ignitor
  • Heat exchanger condition
  • Air intake and exhaust terminations