{"product_id":"pr370-switching-fan-relay-spdt-24-coil-voltage-18-resistive-amps","title":"PR370 \/ 90-370 Switching Fan Relay SPDT 24 Coil Voltage 18 Resistive Amps","description":"\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003ePR370 \/ 90-370 Switching Fan Relay\u003c\/strong\u003e is a versatile \u003cstrong\u003eSPDT fan relay\u003c\/strong\u003e designed for HVAC blower motors, condenser fan motors, electric heating equipment, and general-purpose switching applications. Featuring a \u003cstrong\u003e24 VAC coil\u003c\/strong\u003e and \u003cstrong\u003e18 amp resistive contact rating\u003c\/strong\u003e, this relay provides reliable control of line-voltage loads from low-voltage thermostat or control board signals. Its universal design makes it a popular replacement relay for residential and light commercial HVAC systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePR370\u003c\/li\u003e\n\u003cli\u003e90-370\u003c\/li\u003e\n\u003cli\u003eWhite-Rodgers 90-370\u003c\/li\u003e\n\u003cli\u003eCopeland Comfort Control 90-370\u003c\/li\u003e\n\u003cli\u003eEmerson 90-370\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopeland Comfort Control\u003c\/li\u003e\n\u003cli\u003eWhite-Rodgers\u003c\/li\u003e\n\u003cli\u003eEmerson\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eTrane\u003c\/li\u003e\n\u003cli\u003eAmerican Standard\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eArmstrong Air\u003c\/li\u003e\n\u003cli\u003eUniversal HVAC Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor blower motor control\u003c\/li\u003e\n\u003cli\u003eCondenser fan motor control\u003c\/li\u003e\n\u003cli\u003eElectric heater switching\u003c\/li\u003e\n\u003cli\u003eAir handler relay replacement\u003c\/li\u003e\n\u003cli\u003eFurnace fan relay replacement\u003c\/li\u003e\n\u003cli\u003eHVAC control circuits\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose load switching\u003c\/li\u003e\n\u003cli\u003eLow-voltage controlled power circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContactors\u003c\/li\u003e\n\u003cli\u003eControl transformers\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003cli\u003eFan motors\u003c\/li\u003e\n\u003cli\u003eControl boards\u003c\/li\u003e\n\u003cli\u003eTime delay relays\u003c\/li\u003e\n\u003cli\u003eSequencers\u003c\/li\u003e\n\u003cli\u003eCapacitors\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSPDT (Single Pole Double Throw) relay configuration provides both normally open and normally closed switching functions.\u003c\/li\u003e\n\u003cli\u003e24 VAC coil is compatible with most residential HVAC control systems.\u003c\/li\u003e\n\u003cli\u003eRated for 18 amps resistive loads.\u003c\/li\u003e\n\u003cli\u003eCommonly used for blower motor and fan circuit switching.\u003c\/li\u003e\n\u003cli\u003eUniversal replacement design simplifies service truck inventory.\u003c\/li\u003e\n\u003cli\u003eAlways verify coil voltage and contact ratings before replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor blower will not start\u003c\/li\u003e\n\u003cli\u003eFan runs continuously\u003c\/li\u003e\n\u003cli\u003eIntermittent blower operation\u003c\/li\u003e\n\u003cli\u003eRelay chatter or buzzing\u003c\/li\u003e\n\u003cli\u003eBurned relay contacts\u003c\/li\u003e\n\u003cli\u003eNo voltage transfer across contacts\u003c\/li\u003e\n\u003cli\u003eControl board calls for fan but motor does not energize\u003c\/li\u003e\n\u003cli\u003eVisible overheating or melted housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eLabel all wires before removing the old relay.\u003c\/li\u003e\n\u003cli\u003eVerify coil voltage is 24 VAC.\u003c\/li\u003e\n\u003cli\u003eConfirm contact rating matches application requirements.\u003c\/li\u003e\n\u003cli\u003eInspect terminals for heat damage.\u003c\/li\u003e\n\u003cli\u003eTighten all connections securely.\u003c\/li\u003e\n\u003cli\u003eTest relay operation through a complete heating and cooling cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFan motor amperage draw\u003c\/li\u003e\n\u003cli\u003eTransformer output voltage\u003c\/li\u003e\n\u003cli\u003eThermostat operation\u003c\/li\u003e\n\u003cli\u003eControl board fan signal\u003c\/li\u003e\n\u003cli\u003eRelay terminal condition\u003c\/li\u003e\n\u003cli\u003eWiring integrity\u003c\/li\u003e\n\u003cli\u003eCapacitor condition\u003c\/li\u003e\n\u003cli\u003eContactor operation\u003c\/li\u003e\n\u003cli\u003eGrounding connections\u003c\/li\u003e\n\u003cli\u003eSigns of overheating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003ePR370 Switching Fan Relay SPDT 24 Coil Voltage 18 Resistive Amps\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv id=\"product-tab-heading-0\" class=\"panel-heading\" role=\"tab\"\u003e\n\u003ch3 class=\"panel-title\"\u003e\u003ca role=\"button\" data-toggle=\"collapse\" data-parent=\"#product-accordion\" href=\"https:\/\/www.packardonline.com\/products\/pr370\/#product-tab-0\" aria-expanded=\"true\" aria-controls=\"product-tab-0\" class=\"\"\u003e\u003cspan class=\"product-accordion-title\"\u003eApplications\/Features\u003c\/span\u003e\u003cspan class=\"carrot\" aria-visible=\"false\" role=\"presentation\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"product-tab-0\" class=\"panel-collapse collapse in\" role=\"tabpanel\" aria-labelledby=\"product-tab-heading-0\" aria-expanded=\"true\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e1\/4\" quick connect terminals\u003c\/li\u003e\n\u003cli\u003eUsed for switching solenoids, fan motors, and other applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cimg src=\"https:\/\/packard.blob.core.windows.net\/images-site\/Prop65WARNING.jpg\" alt=\"Calif Prob 65 Warning\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv id=\"product-tab-heading-1\" class=\"panel-heading\" role=\"tab\"\u003e\n\u003ch3 class=\"panel-title\"\u003e\u003ca role=\"button\" data-toggle=\"collapse\" data-parent=\"#product-accordion\" href=\"https:\/\/www.packardonline.com\/products\/pr370\/#product-tab-1\" aria-expanded=\"false\" aria-controls=\"product-tab-1\" class=\"collapsed\"\u003e\u003cspan class=\"product-accordion-title\"\u003eItem Specifications\u003c\/span\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003ctable class=\"table-responsive-simple\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003ePackard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCoil Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContinuous Coil Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCountry of Origin\u003c\/th\u003e\n\u003ctd\u003eCHINA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistive Amps\u003c\/th\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e840899124926\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"product-tab-heading-2\" class=\"panel-heading\" role=\"tab\"\u003e\n\u003ch3 class=\"panel-title\"\u003e\u003ca role=\"button\" data-toggle=\"collapse\" data-parent=\"#product-accordion\" href=\"https:\/\/www.packardonline.com\/products\/pr370\/#product-tab-2\" aria-expanded=\"true\" aria-controls=\"product-tab-2\" class=\"\"\u003e\u003cspan class=\"product-accordion-title\"\u003eDirect replacement for\u003c\/span\u003e\u003cspan class=\"carrot\" aria-visible=\"false\" role=\"presentation\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"product-accordion-title\"\u003e\u003cspan\u003e84-20103-301V\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"product-tab-2\" class=\"panel-collapse collapse in\" role=\"tabpanel\" aria-labelledby=\"product-tab-heading-2\" aria-expanded=\"true\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-responsive-simple\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJard\u003c\/th\u003e\n\u003ctd\u003e92370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMars\u003c\/th\u003e\n\u003ctd\u003e90370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRBM\u003c\/th\u003e\n\u003ctd\u003e90-370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZettler\u003c\/th\u003e\n\u003ctd\u003e2900-1C-24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZettler\u003c\/th\u003e\n\u003ctd\u003eAZ 2900-1C-24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmart Electric\u003c\/th\u003e\n\u003ctd\u003eSE90370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":31637406253122,"sku":"PR370","price":21.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/PR370.jpg?v=1739518584","url":"https:\/\/hvacpartstoremarket.com\/products\/pr370-switching-fan-relay-spdt-24-coil-voltage-18-resistive-amps","provider":"HVACpartstore","version":"1.0","type":"link"}