The PR370 / 90-370 Switching Fan Relay is a versatile SPDT fan relay designed for HVAC blower motors, condenser fan motors, electric heating equipment, and general-purpose switching applications. Featuring a 24 VAC coil and 18 amp resistive contact rating, this relay provides reliable control of line-voltage loads from low-voltage thermostat or control board signals. Its universal design makes it a popular replacement relay for residential and light commercial HVAC systems.


Cross-Reference

  • PR370
  • 90-370
  • White-Rodgers 90-370
  • Copeland Comfort Control 90-370
  • Emerson 90-370

Direct OEM

  • Copeland Comfort Control
  • White-Rodgers
  • Emerson

Compatible Brands

  • Coleman
  • Evcon
  • York
  • Luxaire
  • Fraser-Johnston
  • Goodman
  • Amana
  • Rheem
  • Ruud
  • Carrier
  • Bryant
  • Payne
  • Trane
  • American Standard
  • Lennox
  • Heil
  • Tempstar
  • Armstrong Air
  • Universal HVAC Applications

Application

  • Indoor blower motor control
  • Condenser fan motor control
  • Electric heater switching
  • Air handler relay replacement
  • Furnace fan relay replacement
  • HVAC control circuits
  • General-purpose load switching
  • Low-voltage controlled power circuits

Related Components

  • Contactors
  • Control transformers
  • Thermostats
  • Fan motors
  • Control boards
  • Time delay relays
  • Sequencers
  • Capacitors
  • Limit switches
  • Pressure switches

Technician Notes

  • SPDT (Single Pole Double Throw) relay configuration provides both normally open and normally closed switching functions.
  • 24 VAC coil is compatible with most residential HVAC control systems.
  • Rated for 18 amps resistive loads.
  • Commonly used for blower motor and fan circuit switching.
  • Universal replacement design simplifies service truck inventory.
  • Always verify coil voltage and contact ratings before replacement.

Common Symptoms of Failure

  • Indoor blower will not start
  • Fan runs continuously
  • Intermittent blower operation
  • Relay chatter or buzzing
  • Burned relay contacts
  • No voltage transfer across contacts
  • Control board calls for fan but motor does not energize
  • Visible overheating or melted housing

Installation Tips

  1. Disconnect power before servicing.
  2. Label all wires before removing the old relay.
  3. Verify coil voltage is 24 VAC.
  4. Confirm contact rating matches application requirements.
  5. Inspect terminals for heat damage.
  6. Tighten all connections securely.
  7. Test relay operation through a complete heating and cooling cycle.

Recommended Inspection Items

  • Fan motor amperage draw
  • Transformer output voltage
  • Thermostat operation
  • Control board fan signal
  • Relay terminal condition
  • Wiring integrity
  • Capacitor condition
  • Contactor operation
  • Grounding connections
  • Signs of overheating