PR370 / 90-370 Switching Fan Relay SPDT 24 Coil Voltage 18 Resistive Amps
The PR370 / 90-370 Switching Fan Relay is a versatile SPDT fan relay designed for HVAC blower motors, condenser fan motors, electric heating equipment, and general-purpose switching applications. Featuring a 24 VAC coil and 18 amp resistive contact rating, this relay provides reliable control of line-voltage loads from low-voltage thermostat or control board signals. Its universal design makes it a popular replacement relay for residential and light commercial HVAC systems.
Cross-Reference
- PR370
- 90-370
- White-Rodgers 90-370
- Copeland Comfort Control 90-370
- Emerson 90-370
Direct OEM
- Copeland Comfort Control
- White-Rodgers
- Emerson
Compatible Brands
- Coleman
- Evcon
- York
- Luxaire
- Fraser-Johnston
- Goodman
- Amana
- Rheem
- Ruud
- Carrier
- Bryant
- Payne
- Trane
- American Standard
- Lennox
- Heil
- Tempstar
- Armstrong Air
- Universal HVAC Applications
Application
- Indoor blower motor control
- Condenser fan motor control
- Electric heater switching
- Air handler relay replacement
- Furnace fan relay replacement
- HVAC control circuits
- General-purpose load switching
- Low-voltage controlled power circuits
Related Components
- Contactors
- Control transformers
- Thermostats
- Fan motors
- Control boards
- Time delay relays
- Sequencers
- Capacitors
- Limit switches
- Pressure switches
Technician Notes
- SPDT (Single Pole Double Throw) relay configuration provides both normally open and normally closed switching functions.
- 24 VAC coil is compatible with most residential HVAC control systems.
- Rated for 18 amps resistive loads.
- Commonly used for blower motor and fan circuit switching.
- Universal replacement design simplifies service truck inventory.
- Always verify coil voltage and contact ratings before replacement.
Common Symptoms of Failure
- Indoor blower will not start
- Fan runs continuously
- Intermittent blower operation
- Relay chatter or buzzing
- Burned relay contacts
- No voltage transfer across contacts
- Control board calls for fan but motor does not energize
- Visible overheating or melted housing
Installation Tips
- Disconnect power before servicing.
- Label all wires before removing the old relay.
- Verify coil voltage is 24 VAC.
- Confirm contact rating matches application requirements.
- Inspect terminals for heat damage.
- Tighten all connections securely.
- Test relay operation through a complete heating and cooling cycle.
Recommended Inspection Items
- Fan motor amperage draw
- Transformer output voltage
- Thermostat operation
- Control board fan signal
- Relay terminal condition
- Wiring integrity
- Capacitor condition
- Contactor operation
- Grounding connections
- Signs of overheating
PR370 Switching Fan Relay SPDT 24 Coil Voltage 18 Resistive Amps
- 1/4" quick connect terminals
- Used for switching solenoids, fan motors, and other applications.
Item Specifications
| Brand | Packard |
|---|---|
| Coil Voltage | 24 VAC |
| Continuous Coil Voltage | 24 VAC |
| Country of Origin | CHINA |
| Resistive Amps | 18 |
| UPC |
840899124926 |
Direct replacement for
84-20103-301V
| Jard | 92370 |
|---|---|
| Mars | 90370 |
| RBM | 90-370 |
| Zettler | 2900-1C-24A |
| Zettler | AZ 2900-1C-24A |
| Smart Electric | SE90370 |