PR342 / 90-342 Switching Relay 208-240 Coil Voltage
PR342 / 90-342 Switching Relay 208-240 Coil Voltage
In Stock
The PR342 / 90-342 Switching Relay is a heavy-duty SPDT (Single Pole Double Throw) switching relay designed for HVAC, refrigeration, air handling, and general-purpose electrical control applications. Featuring a 208-240 VAC coil and a five-terminal design, this relay provides dependable switching of motors, contactors, heaters, and control circuits. Commonly used as a direct replacement for White-Rodgers, Honeywell, Mars, and RBM relays, the PR342 offers reliable performance in residential, commercial, and industrial equipment.
Cross-Reference
- PR342
- 90-342
- White-Rodgers 90-342
- Copeland Comfort Control 90-342
- Emerson 90-342
- Mars 90342
- Honeywell R4222D1021
- RBM Equivalent Relay
Direct OEM
- Copeland Comfort Control
- White-Rodgers
- Emerson
Compatible Brands
- Coleman
- York
- Luxaire
- Fraser-Johnston
- Carrier
- Bryant
- Payne
- Goodman
- Amana
- Rheem
- Ruud
- Trane
- American Standard
- Lennox
- Heil
- Tempstar
- Commercial HVAC Equipment
- Refrigeration Equipment
Application
- Blower motor control
- Condenser fan switching
- Electric heating circuits
- Air handler controls
- Commercial HVAC controls
- Refrigeration equipment
- General-purpose motor switching
- Industrial control systems
Related Components
- Contactors
- Fan relays
- Control transformers
- Thermostats
- Time delay relays
- Sequencers
- Motor starters
- Capacitors
- Pressure switches
- Control boards
Technician Notes
- SPDT relay configuration provides both normally open and normally closed contacts.
- Designed for operation with 208-240 VAC control voltage.
- Five-terminal layout simplifies replacement of many OEM relay designs.
- With coil de-energized, terminals 1 & 2 are closed (NC) and 1 & 3 are open (NO).
- When 208-240 VAC is applied to the coil, terminals 1 & 3 close and 1 & 2 open.
- Frequently used to control motors, fans, heaters, and contactors from a line-voltage control circuit.
Common Symptoms of Failure
- Equipment will not start
- Fan motor not energizing
- Relay chatter or buzzing
- Contacts welded closed
- Burned relay terminals
- Intermittent equipment operation
- No voltage transfer through contacts
- Relay coil open or failed
Installation Tips
- Disconnect power before servicing.
- Label all wires before removing the existing relay.
- Verify coil voltage is 208-240 VAC.
- Confirm contact ratings match equipment requirements.
- Inspect terminals for overheating or discoloration.
- Tighten all electrical connections securely.
- Test relay operation after installation.
Recommended Inspection Items
- Relay coil voltage
- Contact condition
- Wiring terminals
- Motor amperage draw
- Control circuit operation
- Transformer output
- Contactor condition
- Wire insulation condition
- Equipment grounding
- Signs of overheating
SPDT (single-pole double-throw) switching relay 208-240V coil voltage. 5 terminals.
The unmarked double terminals are 208-240V input. With no 208-240V power applied: Terminals 1 & 2 are normally closed (NC). Terminals 1 & 3 are normally open (NO). Terminals 2 & 3 are open.
When 208-240V power is applied: Terminals 1 & 2 are opened. Terminals 1 & 3 are closed. Terminals 2 & 3 stay open.
Replaces Mars 90342, RBM & White Rodgers 90-342 and Honeywell R4222D1021 and others.