{"product_id":"mot21480-trane-3-4hp-208-230-60-1-ccw-1050rpm","title":"MOT21480 Trane 3\/4HP 208-230\/60\/1 CCW 1050RPM","description":"\u003ch1\u003eMOT21480 Trane 3\/4HP 208-230\/60\/1 CCW 1050RPM\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eMOT21480 Trane Blower Motor\u003c\/strong\u003e is a genuine OEM replacement motor designed for select Trane and American Standard HVAC systems. Rated at \u003cstrong\u003e3\/4 HP\u003c\/strong\u003e, \u003cstrong\u003e208-230 Volt\u003c\/strong\u003e, \u003cstrong\u003esingle-phase (60 Hz)\u003c\/strong\u003e, and \u003cstrong\u003e1050 RPM\u003c\/strong\u003e, this motor delivers reliable airflow performance for residential and light commercial heating and cooling applications. Featuring \u003cstrong\u003ecounterclockwise rotation (CCW)\u003c\/strong\u003e, the MOT21480 is engineered to meet original equipment specifications for dependable operation, proper airflow, and long service life.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch4\u003eMOT16684\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrane MOT21480\u003c\/li\u003e\n\u003cli\u003eAmerican Standard MOT21480\u003c\/li\u003e\n\u003cli\u003e3\/4 HP Blower Motor\u003c\/li\u003e\n\u003cli\u003e208-230V Blower Motor\u003c\/li\u003e\n\u003cli\u003e1050 RPM Motor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine Trane OEM replacement blower motor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrane\u003c\/li\u003e\n\u003cli\u003eAmerican Standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the unit model and serial number before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential HVAC systems\u003c\/li\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eElectric furnaces\u003c\/li\u003e\n\u003cli\u003eAir handlers\u003c\/li\u003e\n\u003cli\u003ePackage units\u003c\/li\u003e\n\u003cli\u003eBlower assemblies\u003c\/li\u003e\n\u003cli\u003eHeating and cooling air circulation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels\u003c\/li\u003e\n\u003cli\u003eRun capacitors\u003c\/li\u003e\n\u003cli\u003eMotor mounting brackets\u003c\/li\u003e\n\u003cli\u003eFan relays\u003c\/li\u003e\n\u003cli\u003eControl boards\u003c\/li\u003e\n\u003cli\u003eWiring harnesses\u003c\/li\u003e\n\u003cli\u003eAir filters\u003c\/li\u003e\n\u003cli\u003eBlower housings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3\/4 HP motor rating.\u003c\/li\u003e\n\u003cli\u003e208-230 Volt operation.\u003c\/li\u003e\n\u003cli\u003eSingle-phase, 60 Hz.\u003c\/li\u003e\n\u003cli\u003e1050 RPM.\u003c\/li\u003e\n\u003cli\u003eCounterclockwise (CCW) rotation.\u003c\/li\u003e\n\u003cli\u003eVerify shaft size, mounting configuration, and capacitor requirements before installation.\u003c\/li\u003e\n\u003cli\u003eInspect blower wheel condition when replacing the motor.\u003c\/li\u003e\n\u003cli\u003eCheck amperage draw after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBlower motor will not start\u003c\/li\u003e\n\u003cli\u003eWeak airflow\u003c\/li\u003e\n\u003cli\u003eMotor overheating\u003c\/li\u003e\n\u003cli\u003eExcessive bearing noise\u003c\/li\u003e\n\u003cli\u003eMotor hums but does not run\u003c\/li\u003e\n\u003cli\u003eIntermittent operation\u003c\/li\u003e\n\u003cli\u003eHigh-limit trips due to lack of airflow\u003c\/li\u003e\n\u003cli\u003eBlower vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eConfirm motor specifications match the original part.\u003c\/li\u003e\n\u003cli\u003eInspect blower wheel for dirt buildup and balance issues.\u003c\/li\u003e\n\u003cli\u003eReplace the run capacitor if recommended by the manufacturer.\u003c\/li\u003e\n\u003cli\u003eSecure all electrical connections.\u003c\/li\u003e\n\u003cli\u003eVerify correct rotation before final assembly.\u003c\/li\u003e\n\u003cli\u003eCheck system airflow after startup.\u003c\/li\u003e\n\u003cli\u003eMeasure operating amperage to confirm proper performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRun capacitor condition\u003c\/li\u003e\n\u003cli\u003eBlower wheel cleanliness\u003c\/li\u003e\n\u003cli\u003eMotor mounting hardware\u003c\/li\u003e\n\u003cli\u003eFan relay operation\u003c\/li\u003e\n\u003cli\u003eControl board outputs\u003c\/li\u003e\n\u003cli\u003eWiring terminals\u003c\/li\u003e\n\u003cli\u003eAir filter condition\u003c\/li\u003e\n\u003cli\u003eDuctwork restrictions\u003c\/li\u003e\n\u003cli\u003eSystem temperature rise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":46051352281154,"sku":"MOT21480","price":653.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-16201729.png?v=1794885463","url":"https:\/\/hvacpartstoremarket.com\/products\/mot21480-trane-3-4hp-208-230-60-1-ccw-1050rpm","provider":"HVACpartstore","version":"1.0","type":"link"}