{"product_id":"l160-20f-rheem-3-inch-limit-switch-47-25349-01","title":"47-25349-01K Rheem 3-inch limit switch L160-20F","description":"\u003ch1\u003e47-25349-01K Rheem 3-inch limit switch L160-20F  \u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e47-25349-01K Rheem ProTech Limit Switch\u003c\/strong\u003e is a genuine OEM automatic reset temperature safety control designed for use in select Rheem, Ruud, WeatherKing, and Richmond heating systems. Rated \u003cstrong\u003eL160-20F\u003c\/strong\u003e, this safety switch opens at \u003cstrong\u003e160°F\u003c\/strong\u003e and automatically resets when temperatures decrease to approximately \u003cstrong\u003e140°F\u003c\/strong\u003e, helping protect the furnace from overheating conditions and potential component damage.\u003c\/p\u003e\n\u003cp\u003eFeaturing a \u003cstrong\u003e3-inch sensing rod\u003c\/strong\u003e and a compact mounting plate measuring \u003cstrong\u003e1-5\/8\" x 1-7\/16\"\u003c\/strong\u003e, the 47-25349-01K is engineered to original equipment specifications for dependable temperature monitoring and safe furnace operation. This updated replacement supersedes the older \u003cstrong\u003e47-25349-01\u003c\/strong\u003e limit switch.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e47-25349-01K\u003c\/li\u003e\n\u003cli\u003e472534901K\u003c\/li\u003e\n\u003cli\u003e47-25349-01\u003c\/li\u003e\n\u003cli\u003e472534901\u003c\/li\u003e\n\u003cli\u003e44791\u003c\/li\u003e\n\u003cli\u003e36TVH01B3\u003c\/li\u003e\n\u003cli\u003eRheem Limit Switch\u003c\/li\u003e\n\u003cli\u003eL160-20F Limit Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine Rheem ProTech OEM replacement limit switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e47-25349-01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eWeatherKing\u003c\/li\u003e\n\u003cli\u003eRichmond\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify model compatibility using the equipment model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"___1dmoc29 f10pi13n ftgm304 f1enuhaj fdclmfp f1nbblvp fat0sn4 f1ov4xf1 fekwl8i f1lmfglv f1oz7aqm f1abmfm4 f1w619qj f16h0jq8\" role=\"group\" aria-label=\"Table content\"\u003e\n\u003ctable class=\"___h4t1f90 f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 f1y24664 f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i f8u40bk f1sdlqf5 ffufd3x fe1ov7n f1004tna fcoaxci fh0ee9u f15v23i2 f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e47-25349-01K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces\u003c\/td\u003e\n\u003ctd\u003e47-25349-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Rating\u003c\/td\u003e\n\u003ctd\u003eL160-20F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Temperature\u003c\/td\u003e\n\u003ctd\u003e160°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Temperature\u003c\/td\u003e\n\u003ctd\u003e140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Length\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Plate\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\" x 1-7\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Style\u003c\/td\u003e\n\u003ctd\u003e36TVH01B3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eResidential heating systems\u003c\/li\u003e\n\u003cli\u003eHigh-limit temperature protection\u003c\/li\u003e\n\u003cli\u003eHeat exchanger safety circuits\u003c\/li\u003e\n\u003cli\u003eOEM furnace repairs\u003c\/li\u003e\n\u003cli\u003eOver-temperature protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRollout switches\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eFurnace control boards\u003c\/li\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003eHot surface ignitors\u003c\/li\u003e\n\u003cli\u003eBlower motors\u003c\/li\u003e\n\u003cli\u003eAir filters\u003c\/li\u003e\n\u003cli\u003eHeat exchanger components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Rheem ProTech safety control.\u003c\/li\u003e\n\u003cli\u003eOpens at \u003cstrong\u003e160°F\u003c\/strong\u003e and automatically resets at \u003cstrong\u003e140°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e3-inch sensing rod design.\u003c\/li\u003e\n\u003cli\u003eProtects the furnace from overheating conditions.\u003c\/li\u003e\n\u003cli\u003eRepeated limit trips often indicate airflow restrictions, dirty filters, blower motor issues, blocked ductwork, or heat exchanger problems.\u003c\/li\u003e\n\u003cli\u003eAlways diagnose the source of overheating before replacing the limit switch.\u003c\/li\u003e\n\u003cli\u003eInspect wiring terminals for signs of heat damage or corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace shuts down during heating cycle\u003c\/li\u003e\n\u003cli\u003eOpen limit switch fault codes\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously\u003c\/li\u003e\n\u003cli\u003eFurnace lockout conditions\u003c\/li\u003e\n\u003cli\u003eNo heat complaints\u003c\/li\u003e\n\u003cli\u003eHigh temperature safety trips\u003c\/li\u003e\n\u003cli\u003eOverheating-related shutdowns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eConfirm the replacement switch matches the original temperature rating.\u003c\/li\u003e\n\u003cli\u003eInspect wiring terminals and connectors.\u003c\/li\u003e\n\u003cli\u003eInstall the sensing rod fully into the designated mounting location.\u003c\/li\u003e\n\u003cli\u003eSecure the mounting plate properly.\u003c\/li\u003e\n\u003cli\u003eRestore power and monitor operation.\u003c\/li\u003e\n\u003cli\u003eVerify airflow and blower performance.\u003c\/li\u003e\n\u003cli\u003eConfirm proper furnace temperature rise during operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAir filter condition\u003c\/li\u003e\n\u003cli\u003eBlower motor operation\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eVenting system\u003c\/li\u003e\n\u003cli\u003eRollout switches\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eControl board diagnostics\u003c\/li\u003e\n\u003cli\u003eSupply and return airflow\u003c\/li\u003e\n\u003cli\u003eFurnace temperature rise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eRheem Protech 3\" limit switch. L160-20F meaning the switch opens at 160 degrees F and automatically closes at 140 degrees F. Mounting board measures 1-5\/8\" x 1-7\/16\". Also known as part # 472534901 \u0026amp; 44791. Size is 36TVH01B3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces 47-25349-01\u003c\/strong\u003e\u003c\/p\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":13473904131,"sku":"47-25349-01K","price":21.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2268_126724528.jpeg?v=1566072359","url":"https:\/\/hvacpartstoremarket.com\/products\/l160-20f-rheem-3-inch-limit-switch-47-25349-01","provider":"HVACpartstore","version":"1.0","type":"link"}