47-25349-01K Rheem 3-inch limit switch L160-20F
47-25349-01K Rheem 3-inch limit switch L160-20F
The 47-25349-01K Rheem ProTech Limit Switch is a genuine OEM automatic reset temperature safety control designed for use in select Rheem, Ruud, WeatherKing, and Richmond heating systems. Rated L160-20F, this safety switch opens at 160°F and automatically resets when temperatures decrease to approximately 140°F, helping protect the furnace from overheating conditions and potential component damage.
Featuring a 3-inch sensing rod and a compact mounting plate measuring 1-5/8" x 1-7/16", the 47-25349-01K is engineered to original equipment specifications for dependable temperature monitoring and safe furnace operation. This updated replacement supersedes the older 47-25349-01 limit switch.
Cross-Reference
- 47-25349-01K
- 472534901K
- 47-25349-01
- 472534901
- 44791
- 36TVH01B3
- Rheem Limit Switch
- L160-20F Limit Switch
Direct OEM
Yes – Genuine Rheem ProTech OEM replacement limit switch.
Replaces:
- 47-25349-01
Compatible Brands
- Rheem
- Ruud
- WeatherKing
- Richmond
Always verify model compatibility using the equipment model and serial number.
Specifications
| Specification | Value |
|---|---|
| Part Number | 47-25349-01K |
| Replaces | 47-25349-01 |
| Temperature Rating | L160-20F |
| Open Temperature | 160°F |
| Reset Temperature | 140°F |
| Reset Type | Automatic |
| Probe Length | 3" |
| Mounting Plate | 1-5/8" x 1-7/16" |
| Switch Style | 36TVH01B3 |
Application
- Gas furnaces
- Residential heating systems
- High-limit temperature protection
- Heat exchanger safety circuits
- OEM furnace repairs
- Over-temperature protection systems
Related Components
- Rollout switches
- Pressure switches
- Furnace control boards
- Flame sensors
- Hot surface ignitors
- Blower motors
- Air filters
- Heat exchanger components
Technician Notes
- Genuine Rheem ProTech safety control.
- Opens at 160°F and automatically resets at 140°F.
- 3-inch sensing rod design.
- Protects the furnace from overheating conditions.
- Repeated limit trips often indicate airflow restrictions, dirty filters, blower motor issues, blocked ductwork, or heat exchanger problems.
- Always diagnose the source of overheating before replacing the limit switch.
- Inspect wiring terminals for signs of heat damage or corrosion.
Common Symptoms of Failure
- Furnace shuts down during heating cycle
- Open limit switch fault codes
- Intermittent heating operation
- Blower runs continuously
- Furnace lockout conditions
- No heat complaints
- High temperature safety trips
- Overheating-related shutdowns
Installation Tips
- Disconnect power before servicing.
- Confirm the replacement switch matches the original temperature rating.
- Inspect wiring terminals and connectors.
- Install the sensing rod fully into the designated mounting location.
- Secure the mounting plate properly.
- Restore power and monitor operation.
- Verify airflow and blower performance.
- Confirm proper furnace temperature rise during operation.
Recommended Inspection Items
- Air filter condition
- Blower motor operation
- Heat exchanger condition
- Venting system
- Rollout switches
- Pressure switches
- Control board diagnostics
- Supply and return airflow
- Furnace temperature rise
Rheem Protech 3" limit switch. L160-20F meaning the switch opens at 160 degrees F and automatically closes at 140 degrees F. Mounting board measures 1-5/8" x 1-7/16". Also known as part # 472534901 & 44791. Size is 36TVH01B3.
Replaces 47-25349-01