S1-025-22273-002 YORK L140F L250F Coleman combination limit switch with fork
L140F L250F Coleman combination limit switch with fork S1-025-22273-002
The S1‑025‑22273‑002 is a genuine OEM combination limit switch assembly used in York, Coleman, Luxaire, Fraser‑Johnston, and Evcon electric furnaces. This dual‑function safety control incorporates both an L140°F automatic reset limit and an L250°F high‑temperature safety limit within a single fork‑style sensor assembly.
Designed to monitor heater compartment temperatures, this switch protects heating elements, sequencers, wiring, and furnace components from damage caused by restricted airflow or overheating. The OEM fork‑style sensing probe provides accurate temperature monitoring while maintaining the original safety specifications of the furnace.
When temperatures exceed safe operating ranges, the limit switch interrupts the heating circuit to prevent equipment damage and unsafe operating conditions.
🔧 Cross‑Reference (Technician Binder Card Format)
Direct OEM
- S1‑025‑22273‑002
- 025‑22273‑002
- York Source 1 OEM Combination Limit Switch
Compatible Brands
- York
- Coleman
- Luxaire
- Fraser‑Johnston
- Evcon
Specifications
- Primary Limit: L140°F
- Secondary Limit: L250°F
- Style: Fork Sensor
- Type: Combination Limit Switch
- Application: Electric Furnace Heater Assemblies
- OEM Replacement: Yes
Related York / Coleman Combination Limits
(Verify temperature ratings before substitution)
- S1‑025‑22273‑001 — L150F / L250F Combination Limit
- S1‑025‑35380‑000 — L140‑30F Limit Switch
- S1‑025‑31813‑000 — L160‑30F Limit Switch
- S1‑025‑29041‑007 — L170‑30F Limit Switch
🛠️ Technician Notes
- Used primarily in electric furnace heater compartments.
- Fork sensor must be installed in the original factory position.
- Protects electric heat strips from excessive operating temperatures.
- Common replacement symptoms:
- Electric heat not operating
- Open limit condition
- Premature heater shutdown
- Intermittent heat operation
- Repeated limit trips
Always Inspect:
- Heating elements
- Heating sequencers
- Blower motor operation
- Air filter condition
- Supply and return airflow
- Wiring terminals for heat damage
Repeated limit trips usually indicate an airflow issue or failed heating component rather than a defective limit switch alone.
Combination Coleman limit switch with fork L140F and L250F. Open set points are 140 degrees and 250 degrees Fahrenheit. Part number 025-22273-002. Thermodisc size is 75TF014. For use with 2CE, 2MH & 2HE electric heat kits.
140-100F AUTO Limit Switch